Datasheet

MSP430F5510, MSP430F5509, MSP430F5508, MSP430F5507
MSP430F5506, MSP430F5505, MSP430F5504, MSP430F5503
MSP430F5502, MSP430F5501, MSP430F5500
SLAS645I JULY 2009REVISED NOVEMBER 2013
www.ti.com
PMM, SVM Low Side
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
SVMLE = 0, PMMCOREV = 2 0 nA
I
(SVML)
SVM
L
current consumption SVMLE = 1, PMMCOREV = 2, SVMLFP = 0 200 nA
SVMLE = 1, PMMCOREV = 2, SVMLFP = 1 1.5 µA
SVMLE = 1, dV
CORE
/dt = 10 mV/µs, SVMLFP = 1 2.5
t
pd(SVML)
SVM
L
propagation delay µs
SVMLE = 1, dV
CORE
/dt = 1 mV/µs, SVMLFP = 0 20
SVMLE = 0 1, SVMLFP = 1 12.5
t
(SVML)
SVM
L
on or off delay time µs
SVMLE = 0 1, SVMLFP = 0 100
Wake-Up From Low Power Modes and Reset
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
PMMCOREV = SVSMLRRL = n f
MCLK
4.0 MHz 5
t
WAKE-UP-
Wake-up time from LPM2, LPM3, or
(where n = 0, 1, 2, or 3), µs
FAST
LPM4 to active mode
(1)
f
MCLK
< 4.0 MHz 6
SVSLFP = 1
t
WAKE-UP-
Wake-up time from LPM2, LPM3 or PMMCOREV = SVSMLRRL = n
150 165 µs
SLOW
LPM4 to active mode
(2)
(where n = 0, 1, 2, or 3), SVSLFP = 0
t
WAKE-UP-
Wake-up time from LPM4.5 to active
2 3 ms
LPM5
mode
(3)
t
WAKE-UP-
Wake-up time from RST or BOR event to
2 3 ms
RESET
active mode
(3)
(1) This value represents the time from the wakeup event to the first active edge of MCLK. The wakeup time depends on the performance
mode of the low side supervisor (SVS
L
) and low side monitor (SVM
L
). Fastest wakeup times are possible with SVS
L
and SVM
L
in full
performance mode or disabled when operating in AM, LPM0, and LPM1. Various options are available for SVS
L
and SVM
L
while
operating in LPM2, LPM3, and LPM4. See the Power Management Module and Supply Voltage Supervisor chapter in the MSP430x5xx
and MSP430F6xx Family User's Guide (SLAU208).
(2) This value represents the time from the wakeup event to the first active edge of MCLK. The wakeup time depends on the performance
mode of the low side supervisor (SVS
L
) and low side monitor (SVM
L
). In this case, the SVS
L
and SVM
L
are in normal mode (low current)
mode when operating in AM, LPM0, and LPM1. Various options are available for SVS
L
and SVM
L
while operating in LPM2, LPM3, and
LPM4. See the Power Management Module and Supply Voltage Supervisor chapter in the MSP430x5xx and MSP430F6xx Family
User's Guide (SLAU208).
(3) This value represents the time from the wakeup event to the reset vector execution.
Timer_A
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
Internal: SMCLK, ACLK
f
TA
Timer_A input clock frequency External: TACLK 1.8 V, 3 V 25 MHz
Duty cycle = 50% ± 10%
All capture inputs,
t
TA,cap
Timer_A capture timing Minimum pulse duration required for 1.8 V, 3 V 20 ns
capture.
Timer_B
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
Internal: SMCLK, ACLK
f
TB
Timer_B input clock frequency External: TBCLK 1.8 V, 3 V 25 MHz
Duty cycle = 50% ± 10%
All capture inputs, Minimum pulse
t
TB,cap
Timer_B capture timing 1.8 V, 3 V 20 ns
duration required for capture
62 Submit Documentation Feedback Copyright © 2009–2013, Texas Instruments Incorporated
Product Folder Links: MSP430F5510 MSP430F5509 MSP430F5508 MSP430F5507 MSP430F5506 MSP430F5505
MSP430F5504 MSP430F5503 MSP430F5502 MSP430F5501 MSP430F5500