Datasheet
MSP430F5510, MSP430F5509, MSP430F5508, MSP430F5507
MSP430F5506, MSP430F5505, MSP430F5504, MSP430F5503
MSP430F5502, MSP430F5501, MSP430F5500
www.ti.com
SLAS645I –JULY 2009–REVISED NOVEMBER 2013
Schmitt-Trigger Inputs – General Purpose I/O
(1)
(P1.0 to P1.7, P2.0 to P2.7, P3.0 to P3.4, P4.0 to P4.7)
(P5.0 to P5.5, P6.0 to P6.7, PJ.0 to PJ.3, RST/NMI)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
1.8 V 0.80 1.40
V
IT+
Positive-going input threshold voltage V
3 V 1.50 2.10
1.8 V 0.45 1.00
V
IT–
Negative-going input threshold voltage V
3 V 0.75 1.65
1.8 V 0.3 0.85
V
hys
Input voltage hysteresis (V
IT+
– V
IT–
) V
3 V 0.4 1.0
For pullup: V
IN
= V
SS
R
Pull
Pullup or pulldown resistor
(2)
20 35 50 kΩ
For pulldown: V
IN
= V
CC
C
I
Input capacitance V
IN
= V
SS
or V
CC
5 pF
(1) Same parametrics apply to clock input pin when crystal bypass mode is used on XT1 (XIN) or XT2 (XT2IN).
(2) Also applies to the RST pin when its pullup or pullup resistor is enabled.
Inputs – Ports P1 and P2
(1)
(P1.0 to P1.7, P2.0 to P2.7)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN MAX UNIT
Port P1, P2: P1.x to P2.x, External trigger pulse duration
t
(int)
External interrupt timing
(2)
2.2 V, 3 V 20 ns
to set interrupt flag
(1) Some devices may contain additional ports with interrupts. See the block diagram and terminal function descriptions.
(2) An external signal sets the interrupt flag every time the minimum interrupt pulse duration t
(int)
is met. It may be set by trigger signals
shorter than t
(int)
.
Leakage Current – General Purpose I/O
(P1.0 to P1.7, P2.0 to P2.7, P3.0 to P3.4, P4.0 to P4.7)
(P5.0 to P5.5, P6.0 to P6.7, PJ.0 to PJ.3, RST/NMI)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN MAX UNIT
I
lkg(Px.x)
High-impedance leakage current
(1) (2)
1.8 V, 3 V ±50 nA
(1) The leakage current is measured with V
SS
or V
CC
applied to the corresponding pins, unless otherwise noted.
(2) The leakage of the digital port pins is measured individually. The port pin is selected for input and the pullup or pulldown resistor is
disabled.
Outputs – General Purpose I/O (Full Drive Strength)
(P1.0 to P1.7, P2.0 to P2.7, P3.0 to P3.4, P4.0 to P4.7, P5.0 to P5.5, P6.0 to P6.7, PJ.0 to PJ.3)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN MAX UNIT
I
(OHmax)
= –3 mA
(1)
V
CC
– 0.25 V
CC
1.8 V
I
(OHmax)
= –10 mA
(2)
V
CC
– 0.60 V
CC
V
OH
High-level output voltage V
I
(OHmax)
= –5 mA
(1)
V
CC
– 0.25 V
CC
3 V
I
(OHmax)
= –15 mA
(2)
V
CC
– 0.60 V
CC
I
(OLmax)
= 3 mA
(1)
V
SS
V
SS
+ 0.25
1.8 V
I
(OLmax)
= 10 mA
(2)
V
SS
V
SS
+ 0.60
V
OL
Low-level output voltage V
I
(OLmax)
= 5 mA
(1)
V
SS
V
SS
+ 0.25
3 V
I
(OLmax)
= 15 mA
(2)
V
SS
V
SS
+ 0.60
(1) The maximum total current, I
(OHmax)
and I
(OLmax)
, for all outputs combined should not exceed ±48 mA to hold the maximum voltage drop
specified.
(2) The maximum total current, I
(OHmax)
and I
(OLmax)
, for all outputs combined should not exceed ±100 mA to hold the maximum voltage
drop specified.
Copyright © 2009–2013, Texas Instruments Incorporated Submit Documentation Feedback 51
Product Folder Links: MSP430F5510 MSP430F5509 MSP430F5508 MSP430F5507 MSP430F5506 MSP430F5505
MSP430F5504 MSP430F5503 MSP430F5502 MSP430F5501 MSP430F5500