Datasheet
MSP430F532x
SLAS678D –AUGUST 2010–REVISED FEBRUARY 2013
www.ti.com
Electrical Characteristics
Active Mode Supply Current Into V
CC
Excluding External Current
over recommended operating free-air temperature (unless otherwise noted)
(1) (2) (3)
FREQUENCY (f
DCO
= f
MCLK
= f
SMCLK
)
EXECUTION
PARAMETER V
CC
PMMCOREVx 1 MHz 8 MHz 12 MHz 20 MHz 25 MHz UNIT
MEMORY
TYP MAX TYP MAX TYP MAX TYP MAX TYP MAX
0 0.36 0.47 2.32 2.60
1 0.40 2.65 4.0 4.4
I
AM, Flash
Flash 3 V mA
2 0.44 2.90 4.3 7.1 7.7
3 0.46 3.10 4.6 7.6 10.1 11.0
0 0.20 0.24 1.20 1.30
1 0.22 1.35 2.0 2.2
I
AM, RAM
RAM 3 V mA
2 0.24 1.50 2.2 3.7 4.2
3 0.26 1.60 2.4 3.9 5.3 6.2
(1) All inputs are tied to 0 V or to V
CC
. Outputs do not source or sink any current.
(2) The currents are characterized with a Micro Crystal MS1V-T1K crystal with a load capacitance of 12.5 pF. The internal and external load
capacitance are chosen to closely match the required 12.5 pF.
(3) Characterized with program executing typical data processing. LDO disabled (LDOEN = 0).
f
ACLK
= 32786 Hz, f
DCO
= f
MCLK
= f
SMCLK
at specified frequency.
XTS = CPUOFF = SCG0 = SCG1 = OSCOFF = SMCLKOFF = 0.
42 Submit Documentation Feedback Copyright © 2010–2013, Texas Instruments Incorporated