Datasheet
MSP430F5172, MSP430F5152, MSP430F5132
MSP430F5171, MSP430F5151, MSP430F5131
SLAS619J –AUGUST 2010–REVISED OCTOBER 2013
www.ti.com
Timer_D, Power Supply and Reference Clock Conditions
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
(1)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
DV
CC
Digital supply voltage V
(DVSS)
= 0 V 1.8 3.6 V
1.8 V
PMMCOREVx = 0 ≤ V
CC
8 12.0
≤ 3.6 V
2.0 V
PMMCOREVx = 1 ≤ V
CC
8 16.0
Timer_D input
≤ 3.6 V
f
REF,DCO
reference clock MHz
2.2 V
frequency
PMMCOREVx = 2 ≤ V
CC
8 20.0
≤ 3.6 V
2.4 V
PMMCOREVx = 3 ≤ V
CC
8 25.5
≤ 3.6 V
I
(DVCC)
at 64-MHz
f
reference
= 8 MHz, MCx = 0, TDHREGEN = 1,
I
(64MHz)
Timer_D clock, clock 253 320 µA
TDHMx = 0, TDHCLKCR = 0
generator only
I
(DVCC)
at 128-MHz
f
reference
= 16 MHz, MCx = 0, TDHREGEN = 1,
I
(128MHz)
Timer_D clock, clock 285 360 µA
TDHMx = 0, TDHCLKCR = 0
generator only
I
(DVCC)
at 200-MHz
f
reference
= 25 MHz, MCx = 0, TDHREGEN = 1,
I
(200MHz)
Timer_D clock, clock 280 345 µA
TDHMx = 0, TDHCLKCR = 1
generator only
I
(DVCC)
at 256-MHz
f
reference
= 16 MHz, MCx = 0, TDHREGEN = 1,
I
(256MHz)
Timer_D clock, clock 265 330 µA
TDHMx = 1, TDHCLKCR = 1
generator only
2.2 V 244
I
(0,16,64)
I
(DVCC)
TDHCLKRx = 0, TDHCLKSRx = 16, TDHCLKTRIM = 64 µA
3.0 V 295 325
2.2 V 282
I
(1,16,64)
I
(DVCC)
TDHCLKRx = 1, TDHCLKSRx = 16, TDHCLKTRIM = 64 µA
3.0 V 300 400
2.2 V 358
I
(2,16,64)
I
(DVCC)
TDHCLKRx = 2, TDHCLKSRx = 16, TDHCLKTRIM = 64 µA
3.0 V 414 470
(1) The leakage current is defined in the leakage current table with P6.x/Ax parameter.
66 Submit Documentation Feedback Copyright © 2010–2013, Texas Instruments Incorporated
Product Folder Links: MSP430F5172 MSP430F5152 MSP430F5132 MSP430F5171 MSP430F5151 MSP430F5131