Datasheet
MSP430x43x1, MSP430x43x, MSP430x44x1, MSP430x44x
MIXED SIGNAL MICROCONTROLLER
SLAS344G − JANUARY 2002 − REVISED OCTOBER 2009
24
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
operating modes
The MSP430 has one active mode and five software selectable low-power modes of operation. An interrupt
event can wake up the device from any of the five low-power modes, service the request and restore back to
the low-power mode on return from the interrupt program.
The following six operating modes can be configured by software:
D Active mode (AM)
− All clocks are active
D Low-power mode 0 (LPM0)
− CPU is disabled
− ACLK and SMCLK remain active, MCLK is disabled
− FLL+ loop control remains active
D Low-power mode 1 (LPM1)
− CPU is disabled
− FLL+ loop control is disabled
− ACLK and SMCLK remain active, MCLK is disabled
D Low-power mode 2 (LPM2)
− CPU is disabled
− MCLK, FLL+ loop control, and DCOCLK are disabled
− DCO’s dc generator remains enabled
− ACLK remains active
D Low-power mode 3 (LPM3)
− CPU is disabled
− MCLK, FLL+ loop control, and DCOCLK are disabled
− DCO’s dc generator is disabled
− ACLK remains active
D Low-power mode 4 (LPM4)
− CPU is disabled
− ACLK is disabled
− MCLK, FLL+ loop control, and DCOCLK are disabled
− DCO’s dc generator is disabled
− Crystal oscillator is stopped