Datasheet

MSP430x41x
MIXED SIGNAL MICROCONTROLLER
SLAS340J − MAY 2001 − REVISED DECEMBER 2008
21
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
recommended operating conditions
PARAMETER MIN NOM MAX UNITS
Supply voltage during program execution,
V
CC
(AV
CC
= DV
CC
= V
CC
) (see Note 1)
MSP430x41x 1.8 3.6 V
Suppl
y
volta
g
e durin
g
pro
g
ram execution, SVS enabled and PORON = 1,
MSP430x412/413 2.2 3.6
V
Supply
voltage
during
program
execution
,
SVS
enabled
and
PORON
=
1
,
V
CC
(AV
CC
= DV
CC
= V
CC
) (see Note 1 and Note 2)
MSP430x415/417 2.0 3.6
V
Supply voltage during programming of flash memory,
V
CC
(AV
CC
= DV
CC
= V
CC
)
MSP430F41x 2.7 3.6 V
Supply voltage, V
SS
(AV
SS/1/2
= DV
SS
= V
SS
) 0 0 V
Operating free-air temperature range, T
A
MSP430x41x −40 85 °C
LFXT1 t l f f
LF selected, XTS_FLL=0 Watch crystal 32768 Hz
LFXT1 crystal frequency, f
(LFXT1)
(see Note 3)
XT1 selected, XTS_FLL=1 Ceramic resonator 450 8000
kHz
(
see
N
o
t
e
3)
XT1 selected, XTS_FLL=1 Crystal 1000 8000
kHz
Processor frequency (signal MCLK) f
V
CC
= 1.8 V DC 4.15
MHz
Processor frequency (signal MCLK), f
(System)
V
CC
= 3.6 V DC 8
MHz
NOTES: 1. It is recommended to power AV
CC
and DV
CC
from the same source. A maximum difference of 0.3 V between AV
CC
and DV
CC
can
be tolerated during power up and operation.
2. The minimum operating supply voltage is defined according to the trip point where POR is going active by decreasing supply voltage.
POR is going inactive when the supply voltage is raised above minimum supply voltage plus the hysteresis of the SVS circuitry.
3. In LF mode, the LFXT1 oscillator requires a watch crystal. In XT1 mode, LFXT1 accepts a ceramic resonator or a crystal.
f (MHz)
1.8 V 3.6 V
2.7 V 3 V
4.15 MHz
8 MHz
V
CC
− Supply Voltage − V
f
(System)
− Maximum Processor Frequency − MHz
Supply Voltage Range, x41x
During Program Execution
Supply Voltage Range
During Programming of
the Flash Memory
Figure 1. Frequency vs Supply Voltage