Datasheet

MSP430x41x
MIXED SIGNAL MICROCONTROLLER
SLAS340J − MAY 2001 − REVISED DECEMBER 2008
30
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
electrical characteristics over recommended operating free-air temperature (unless otherwise
noted) (continued)
POR brownout, reset (see Notes 1 and 2)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
t
d(BOR)
2000 μs
V
CC(start)
dV
CC
/dt 3 V/s (see Figure 14) 0.7 × V
(B_IT−)
V
V
(B_IT−)
Brownout
dV
CC
/dt 3 V/s (see Figure 14, Figure 15, Figure 16) 1.71 V
V
hys(B_IT−)
B
rownout
dV
CC
/dt 3 V/s (see Figure 14) 70 130 180 mV
t
(reset)
Pulse length needed at RST/NMI pin to accepted reset internally,
V
CC
= 2.2 V/3 V
2 μs
NOTES: 1. The current consumption of the brownout module is already included in the I
CC
current consumption data. The voltage level
V
(B_IT−)
+ V
hys(B_IT−)
is 1.8 V.
2. During power up, the CPU begins code execution following a period of t
d(BOR)
after V
CC
= V
(B_IT−)
+ V
hys(B_IT−)
. The default FLL+
settings must not be changed until V
CC
V
CC(min)
. See the MSP430x4xx Family Users Guide (SLAU056) for more information on
the brownout/SVS circuit.
0
1
V
V
CC(start)
V
hys(B_IT−)
V
CC
t
d(BOR)
(B_IT−)
Figure 14. POR/Brownout Reset (BOR) vs Supply Voltage