Datasheet

MSP430F21x2
SLAS578J NOVEMBER 2007 REVISED JANUARY 2012
www.ti.com
Low-Power-Mode Supply Currents (Into V
CC
) Excluding External Current
(1)(2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS T
A
V
CC
MIN TYP MAX UNIT
f
MCLK
= 0 MHz, -40°C to 85°C 55 66
2.2 V
f
SMCLK
= f
DCO
= 1 MHz,
105°C 68
f
ACLK
= 32768 Hz,
Low-power mode 0
-40°C to 85°C 70 83
I
LPM0, 1MHz
BCSCTL1 = CALBC1_1MHZ, µA
(LPM0) current
(3)
DCOCTL = CALDCO_1MHZ,
3 V
CPUOFF = 1, SCG0 = 0, SCG1 = 0,
105°C 90
OSCOFF = 0
f
MCLK
= 0 MHz, -40°C to 85°C 33 42
2.2 V
f
SMCLK
= f
DCO
(0, 0) 100 kHz,
105°C 44
I
LPM0,
Low-power mode 0 f
ACLK
= 0 Hz,
µA
-40°C to 85°C 37 46
100kHz
(LPM0) current
(3)
RSELx = 0, DCOx = 0,
3 V
CPUOFF = 1, SCG0 = 0, SCG1 = 0,
105°C 48
OSCOFF = 1
f
MCLK
= f
SMCLK
= 0 MHz, -40°C to 85°C 20 25
2.2 V
f
DCO
= 1 MHz,
105°C 27
f
ACLK
= 32768 Hz,
Low-power mode 2
-40°C to 85°C 22 27
I
LPM2
BCSCTL1 = CALBC1_1MHZ, µA
(LPM2) current
(4)
DCOCTL = CALDCO_1MHZ,
3 V
CPUOFF = 1, SCG0 = 0, SCG1 = 1,
105°C 31
OSCOFF = 0
-40°C to 25°C 0.7 1.2
85°C 2.2 V 1.6 2.3
f
DCO
= f
MCLK
= f
SMCLK
= 0 MHz,
105°C 3 6
I
LPM3,
Low-power mode 3 f
ACLK
= 32768 Hz,
µA
LFXT1
(LPM3) current
(4)
CPUOFF = 1, SCG0 = 1, SCG1 = 1,
-40°C to 25°C 0.9 1.9
OSCOFF = 0
85°C 3 V 1.6 2.8
105°C 3 7
-40°C to 25°C 0.3 0.7
85°C 2.2 V 1.2 1.9
f
DCO
= f
MCLK
= f
SMCLK
= 0 MHz,
f
ACLK
from internal LF oscillator
105°C 2 5
Low-power mode 3
I
LPM3, VLO
(VLO), µA
current, (LPM3)
(4)
-40°C to 25°C 0.7 0.8
CPUOFF = 1, SCG0 = 1, SCG1 = 1,
OSCOFF = 0
85°C 3 V 1.4 2.1
105°C 2.5 6
-40°C 0.1 0.5
f
DCO
= f
MCLK
= f
SMCLK
= 0 MHz,
25°C 0.1 0.5
Low-power mode 4 f
ACLK
= 0 Hz,
I
LPM4
2.2 V/ 3 V µA
(LPM4) current
(5)
CPUOFF = 1, SCG0 = 1, SCG1 = 1,
85°C 0.8 1.5
OSCOFF = 1
105°C 2 4
(1) All inputs are tied to 0 V or V
CC
. Outputs do not source or sink any current.
(2) The currents are characterized with a Micro Crystal CC4V-T1A SMD crystal with a load capacitance of 9 pF. The internal and external
load capacitance is chosen to closely match the required 9 pF.
(3) Current for brownout and WDT clocked by SMCLK included.
(4) Current for brownout and WDT clocked by ACLK included.
(5) Current for brownout included.
20 Submit Documentation Feedback Copyright © 20072012, Texas Instruments Incorporated