Datasheet

MSP430F2013-EP
SLAS774A JULY 2011 REVISED OCTOBER 2011
www.ti.com
POR/Brownout Reset (BOR)
(1)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
0.7 ×
V
CC(start)
See Figure 9 dV
CC
/dt 3 V/s V
V
(B_IT-)
V
(B_IT-)
See Figure 9 through Figure 11 dV
CC
/dt 3 V/s 1.71 V
V
hys(B_IT-)
See Figure 9 dV
CC
/dt 3 V/s 70 155 210 mV
t
d(BOR)
See Figure 9
(2)
2000 µs
Pulse length needed at RST/NMI pin to
t
(reset)
2.2 V/3 V 2 µs
accepted reset internally
(2)
(1) The current consumption of the brownout module is already included in the I
CC
current consumption data. The voltage level V
(B_IT-)
+
V
hys(B_IT-)
is 1.8 V.
(2) Minimum and maximum parameters are characterized up to T
A
= 105°C unless otherwise noted.
Figure 9. POR/Brownout Reset (BOR) vs Supply Voltage
20 Submit Documentation Feedback Copyright © 2011, Texas Instruments Incorporated