Datasheet
MSP430F20x3
MSP430F20x2
MSP430F20x1
www.ti.com
SLAS491I –AUGUST 2005–REVISED DECEMBER 2012
Outputs (Ports P1 and P2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
I
(OHmax)
= -1.5 mA
(1)
2.2 V V
CC
- 0.25 V
CC
I
(OHmax)
= -6 mA
(2)
2.2 V V
CC
- 0.6 V
CC
V
OH
High-level output voltage V
I
(OHmax)
= -1.5 mA
(1)
3 V V
CC
- 0.25 V
CC
I
(OHmax)
= -6 mA
(2)
3 V V
CC
- 0.6 V
CC
I
(OLmax)
= 1.5 mA
(1)
2.2 V V
SS
V
SS
+ 0.25
I
(OLmax)
= 6 mA
(2)
2.2 V V
SS
V
SS
+ 0.6
V
OL
Low-level output voltage V
I
(OLmax)
= 1.5 mA
(1)
3 V V
SS
V
SS
+ 0.25
I
(OLmax)
= 6 mA
(2)
3 V V
SS
V
SS
+ 0.6
(1) The maximum total current, I
(OHmax)
and I
(OLmax)
, for all outputs combined should not exceed ±12 mA to hold the maximum voltage drop
specified.
(2) The maximum total current, I
(OHmax)
and I
(OLmax)
, for all outputs combined should not exceed ±48 mA to hold the maximum voltage drop
specified.
Output Frequency (Ports P1 and P2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
2.2 V 10
Port output frequency
f
Px.y
P1.4/SMCLK, C
L
= 20 pF, R
L
= 1 kΩ
(1) (2)
MHz
(with load)
3 V 12
2.2 V 12
f
Port°CLK
Clock output frequency P2.0/ACLK, P1.4/SMCLK, C
L
= 20 pF
(2)
MHz
3 V 16
(1) A resistive divider with 2 × 0.5 kΩ between V
CC
and V
SS
is used as load. The output is connected to the center tap of the divider.
(2) The output voltage reaches at least 10% and 90% V
CC
at the specified toggle frequency.