Datasheet
0
1
t
d(BOR)
V
CC
V
(B_IT−)
V
hys(B_IT−)
V
CC(start)
MSP430AFE2x3
MSP430AFE2x2
MSP430AFE2x1
www.ti.com
SLAS701A –NOVEMBER 2010–REVISED MARCH 2011
POR/Brownout Reset (BOR)
(1) (2)
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS V
CC
MIN TYP MAX UNIT
0.7 ×
V
CC(start)
See Figure 9 dV
CC
/dt ≤ 3 V/s V
V
(B_IT-)
V
(B_IT-)
See Figure 9 through Figure 11 dV
CC
/dt ≤ 3 V/s 1.42 V
V
hys(B_IT-)
See Figure 9 dV
CC
/dt ≤ 3 V/s 120 mV
t
d(BOR)
See Figure 9 2000 µs
Pulse length needed at RST/NMI pin
t
(reset)
3 V 2 µs
to accepted reset internally
(1) The current consumption of the brownout module is already included in the I
CC
current consumption data. The voltage level V
(B_IT-)
+
V
hys(B_IT- )
is ≤ 1.8 V.
(2) During power up, the CPU begins code execution following a period of t
d(BOR)
after V
CC
= V
(B_IT-)
+ V
hys(B_IT-)
. The default DCO settings
must not be changed until V
CC
≥ V
CC(min)
, where V
CC(min)
is the minimum supply voltage for the desired operating frequency.
Figure 9. POR/Brownout Reset (BOR) vs Supply Voltage
Copyright © 2010–2011, Texas Instruments Incorporated Submit Documentation Feedback 21