Datasheet

MSP430F5229, MSP430F5227, MSP430F5224, MSP430F5222
MSP430F5219, MSP430F5217, MSP430F5214, MSP430F5212
www.ti.com
SLAS718D NOVEMBER 2012REVISED OCTOBER 2013
PMM, SVM Low Side
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
SVMLE = 0, PMMCOREV = 2 0 nA
I
(SVML)
SVM
L
current consumption SVMLE= 1, PMMCOREV = 2, SVMLFP = 0 200 nA
SVMLE= 1, PMMCOREV = 2, SVMLFP = 1 1.5 µA
SVMLE = 1, dV
CORE
/dt = 10 mV/µs,
2.5
SVMLFP = 1
t
pd(SVML)
SVM
L
propagation delay µs
SVMLE = 1, dV
CORE
/dt = 1 mV/µs,
20
SVMLFP = 0
SVMLE = 0 1, dV
CORE
/dt = 10 mV/µs,
12.5
SVMLFP = 1
t
(SVML)
SVM
L
on or off delay time µs
SVMLE = 0 1, dV
CORE
/dt = 1 mV/µs,
100
SVMLFP = 0
Wake-Up From Low-Power Modes and Reset
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
f
MCLK
4.0 MHz 3.5 7.5
Wake-up time from LPM2, PMMCOREV = SVSMLRRL = n
t
WAKE-UP-FAST
LPM3, or LPM4 to active (where n = 0, 1, 2, or 3), µs
1.0 MHz < f
MCLK
<
4.5 9
mode
(1)
SVSLFP = 1
4.0 MHz
Wake-up time from LPM2, PMMCOREV = SVSMLRRL = n
t
WAKE-UP-SLOW
LPM3 or LPM4 to active (where n = 0, 1, 2, or 3), 150 175 µs
mode
(2)
SVSLFP = 0
Wake-up time from LPM4.5
t
WAKE-UP-LPM5
2 3 ms
to active mode
(3)
Wake-up time from RST or
t
WAKE-UP-RESET
2 3 ms
BOR event to active mode
(3)
(1) This value represents the time from the wakeup event to the first active edge of MCLK. The wakeup time depends on the performance
mode of the low side supervisor (SVS
L
) and low side monitor (SVM
L
). Fastest wakeup times are possible with SVS
L
and SVM
L
in full
performance mode or disabled when operating in AM, LPM0, and LPM1. Various options are available for SVS
L
and SVM
L
while
operating in LPM2, LPM3, and LPM4. See the Power Management Module and Supply Voltage Supervisor chapter in the MSP430x5xx
and MSP430x6xx Family User's Guide (SLAU208).
(2) This value represents the time from the wakeup event to the first active edge of MCLK. The wakeup time depends on the performance
mode of the low side supervisor (SVS
L
) and low side monitor (SVM
L
). In this case, the SVS
L
and SVM
L
are in normal mode (low current)
mode when operating in AM, LPM0, and LPM1. Various options are available for SVS
L
and SVM
L
while operating in LPM2, LPM3, and
LPM4. See the Power Management Module and Supply Voltage Supervisor chapter in the MSP430x5xx and MSP430x6xx Family User's
Guide (SLAU208).
(3) This value represents the time from the wakeup event to the reset vector execution.
Copyright © 2012–2013, Texas Instruments Incorporated Submit Documentation Feedback 67
Product Folder Links: MSP430F5229 MSP430F5227 MSP430F5224 MSP430F5222 MSP430F5219 MSP430F5217
MSP430F5214 MSP430F5212