Datasheet
"#$%$&
SBAS203J − MARCH 2002 − REVISED JANUARY 2008
www.ti.com
81
Low Voltage Detect Control (LVDCON)
7 6 5 4 3 2 1 0 Reset Value
SFR E7h ALVDIS ALVD2 ALVD1 ALVD0 DLVDIS DLVD2 DLVD1 DLVD0 00h
NOTE: By default, both analog and digital low-voltage detections are enabled, which causes approximately 25µA of
current consumption from the power supply. To minimize this power consumption, both low-voltage detections should be
disabled before entering Stop mode.
ALVDIS Analog Low Voltage Detect Disable.
bit 7 0 = Enable Detection of Low Analog Supply Voltage
1 = Disable Detection of Low Analog Supply Voltage
ALVD2−0 Analog Voltage Detection Level.
bits 6−4
ALVD2 ALVD1 ALVD0 VOLTAGE LEVEL
0 0 0 AV
DD
2.7V (default)
0 0 1 AV
DD
3.0V
0 1 0 AV
DD
3.3V
0 1 1 AV
DD
4.0V
1 0 0 AV
DD
4.2V
1 0 1 AV
DD
4.5V
1 1 0 AV
DD
4.7V
1 1 1 External Voltage AIN7 compared to
1.2V
DLVDIS Digital Low Voltage Detect Disable.
bit 3 0 = Enable Detection of Low Digital Supply Voltage
1 = Disable Detection of Low Digital Supply Voltage
DLVD2−0 Digital Voltage Detection Level.
bits 2−0
DLVD2 DLVD1 DLVD0 VOLTAGE LEVEL
0 0 0 DV
DD
2.7V (default)
0 0 1 DV
DD
3.0V
0 1 0 DV
DD
3.3V
0 1 1 DV
DD
4.0V
1 0 0 DV
DD
4.2V
1 0 1 DV
DD
4.5V
1 1 0 DV
DD
4.7V
1 1 1 External Voltage AIN6 compared to
1.2V