Datasheet

www.ti.com
Absolute Maximum Ratings
(1)
Recommended Operating Conditions
MC33078
DUAL HIGH-SPEED LOW-NOISE OPERATIONAL AMPLIFIER
SLLS633C OCTOBER 2004 REVISED NOVEMBER 2006
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC+
Supply voltage
(2)
18 V
V
CC–
Supply voltage
(2)
–18 V
V
CC+
V
CC–
Supply voltage 36 V
Input voltage, either input
(2) (3)
V
CC+
or V
CC–
V
Input current
(4)
± 10 mA
Duration of output short circuit
(5)
Unlimited
D package 97
θ
JA
Package thermal impedance, junction to free air
(6) (7)
DGK package 172 ° C/W
P package 85
T
J
Operating virtual junction temperature 150 ° C
T
stg
Storage temperature range –65 150 ° C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values, except differential voltages, are with respect to the midpoint between V
CC+
and V
CC–
.
(3) The magnitude of the input voltage must never exceed the magnitude of the supply voltage.
(4) Excessive input current will flow if a differential input voltage in excess of approximately 0.6 V is applied between the inputs, unless
some limiting resistance is used.
(5) The output may be shorted to ground or either power supply. Temperature and/or supply voltages must be limited to ensure the
maximum dissipation rating is not exceeded.
(6) Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) T
A
)/ θ
JA
. Operating at the absolute maximum T
J
of 150 ° C can affect reliability.
(7) The package thermal impedance is calculated in accordance with JESD 51-7.
MIN MAX UNIT
V
CC–
–5 –18
Supply voltage V
V
CC+
5 18
T
A
Operating free-air temperature range –40 85 ° C
2