Datasheet

MC33063A
MC34063A
SLLS636M DECEMBER 2004 REVISED JANUARY 2011
www.ti.com
Output Switch
(1)
PARAMETER TEST CONDITIONS T
A
MIN TYP MAX UNIT
Saturation voltage
V
CE(sat)
I
SW
= 1 A, pins 1 and 8 connected Full range 1 1.3 V
Darlington connection
Saturation voltage I
SW
= 1 A, R
PIN8
= 82 to V
CC
,
V
CE(sat)
Full range 0.45 0.7 V
non-Darlington connection
(2)
forced β 20
h
FE
DC current gain I
SW
= 1 A, V
CE
= 5 V 25°C 50 75
I
C(off)
Collector off-state current V
CE
= 40 V Full range 0.01 100 μA
(1) Low duty-cycle pulse testing is used to maintain junction temperature as close to ambient temperature as possible.
(2) In the non-Darlington configuration, if the output switch is driven into hard saturation at low switch currents (300 mA) and high driver
currents (30 mA), it may take up to 2 μs for the switch to come out of saturation. This condition effectively shortens the off time at
frequencies 30 kHz, becoming magnified as temperature increases. The following output drive condition is recommended in the
non-Darlington configuration:
Forced β of output switch = I
C,SW
/ (I
C,driver
7 mA) 10, where 7 mA is required by the 100- resistor in the emitter of the driver to
forward bias the V
be
of the switch.
Comparator
PARAMETER TEST CONDITIONS T
A
MIN TYP MAX UNIT
25°C 1.225 1.25 1.275
V
th
Threshold voltage V
Full range 1.21 1.29
ΔV
th
Threshold-voltage line regulation V
CC
= 5 V to 40 V Full range 1.4 5 mV
I
IB
Input bias current V
IN
= 0 V Full range 20 400 nA
Total Device
PARAMETER TEST CONDITIONS T
A
MIN MAX UNIT
V
CC
= 5 V to 40 V, C
T
= 1 nF,
I
CC
Supply current V
PIN7
= V
CC
, V
PIN5
> V
th
, Full range 4 mA
V
PIN2
= GND, All other pins open
4 Submit Documentation Feedback Copyright © 20042011, Texas Instruments Incorporated
Product Folder Link(s): MC33063A MC34063A