Datasheet

MAX3318E
SLLS741A JUNE 2006REVISED OCTOBER 2013
www.ti.com
Receiver Section Electrical Characteristics
over recommended ranges of supply voltage and operating free-air temperature,
V
CC
= 2.25 V to 3 V, C1–C4 = 0.1 μF, T
A
= T
MIN
to T
MAX
(unless otherwise noted) (see Figure 4)
PARAMETER TEST CONDITIONS MIN TYP
(1)
MAX UNIT
Input voltage range –25 25 V
Input threshold low T
A
= 25°C 0.3 × V
CC
V
Input threshold high T
A
= 25°C 0.7 × V
CC
V
Input hysteresis 0.3 V
Input resistance T
A
= 25°C 3 5 7 k
Output leakage current ±0.05 ±10 μA
Output voltage low I
OUT
= 0.5 mA 0.1 × V
CC
V
Output voltage high I
OUT
= 0.5 mA 0.9 × V
CC
V
(1) Typical values are at V
CC
= 2.5 V, T
A
= 25°C.
Receiver Section Switching Characteristics
over recommended ranges of supply voltage and operating free-air temperature,
V
CC
= 2.25 V to 3 V, C1–C4 = 0.1 μF, T
A
= T
MIN
to T
MAX
(unless otherwise noted) (see Figure 4)
PARAMETER TEST CONDITIONS TYP
(1)
UNIT
t
PHL
0.175
Receiver propagation delay RIN to ROUT, C
L
= 150 pF μs
t
PLH
0.175
|t
PHL
t
PLH
| Receiver skew
(2)
50 ns
(1) Typical values are at V
CC
= 2.5 V, T
A
= 25°C.
(2) Pulse skew is defined as |t
PLH
t
PHL
| of each channel of the same device.
Auto-Power-Down Plus Section Electrical Characteristics
over recommended ranges of supply voltage and operating free-air temperature,
V
CC
= 2.25 V to 3 V, C1–C4 = 0.1 μF, T
A
= T
MIN
to T
MAX
(unless otherwise noted) (see Figure 4)
PARAMETER TEST CONDITIONS MIN MAX UNIT
Positive threshold 2.7
Receiver input threshold to INVALID high V
Negative threshold –2.7
Receiver input threshold INVALID low –0.3 0.3 V
INVALID, READY voltage low I
OUT
= 0.5 mA 0.1 × V
CC
V
INVALID, READY voltage high I
OUT
= 0.5 mA 0.8 × V
CC
V
Auto-Power-Down Plus Section Switching Characteristics
over recommended ranges of supply voltage and operating free-air temperature,
V
CC
= 2.25 V to 3 V, C1–C4 = 0.1 μF, T
A
= T
MIN
to T
MAX
(unless otherwise noted) (see Figure 4)
PARAMETER TEST CONDITIONS MIN TYP
(1)
MAX UNIT
t
INVH
Receiver positive or negative threshold to INVALID high V
CC
= 2.5 V 1 μs
t
INVL
Receiver positive or negative threshold to INVALID low V
CC
= 2.5 V 30 μs
t
WU
Receiver or driver edge to driver enabled V
CC
= 2.5 V 100 μs
t
AUTOPRDN
Receiver or driver edge to driver shutdown V
CC
= 2.5 V 15 30 60 s
(1) Typical values are at V
CC
= 2.5 V, T
A
= 25°C.
6 Submit Documentation Feedback Copyright © 2006–2013, Texas Instruments Incorporated
Product Folder Links: MAX3318E