Datasheet
MAX3318E
SLLS741A –JUNE 2006–REVISED OCTOBER 2013
www.ti.com
Absolute Maximum Ratings
(1)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
to GND –0.3 6 V
V+ to GND
(2)
–0.3 7 V
V– to GND
(2)
–7 0.3 V
V+ + IV-I
(2)
13 V
DIN, FORCEON, FORCEOFF to GND –0.3 6
Input voltage V
RIN to GND ±25
DOUT to GND ±13.2
Output voltage V
ROUT, INVALID, READY to GND –0.3 V
CC
+ 0.3
Short-circuit duration DOUT to GND Continuous
16-pin SSOP (derate 7.14 mW/°C above 70°C) 571
Continuous power dissipation (T
A
= 70°C) 20-pin SSOP (derate 8 mW/°C above 70°C 640 mW
20-pin TSSOP (derate 7 mW/°C above 70°C) 559
Storage temperature range –65 150 °C
Lead temperature (soldering, 10 s) 300 °C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) V+ and V– can have maximum magnitudes of 7 V, but their absolute difference cannot exceed 13 V.
Recommended Operating Conditions
See Figure 4
MIN NOM MAX UNIT
Supply voltage 2.25 2.5 3 V
DIN, FORCEOFF,
V
IH
Driver and control high-level input voltage V
CC
= 2.5 V to 3 V 0.7 × V
CC
5.5 V
FORCEON
DIN, FORCEOFF,
V
IL
Driver and control low-level input voltage V
CC
= 2.5 V to 3 V 0 0.3 × V
CC
V
FORCEON
V
I
Receiver input voltage –25 25 V
MAX3318EC 0 70
T
A
Operating free-air temperature °C
MAX3318EI –40 85
4 Submit Documentation Feedback Copyright © 2006–2013, Texas Instruments Incorporated
Product Folder Links: MAX3318E