Datasheet
www.ti.com
RECEIVER SECTION – SWITCHING CHARACTERISTICS
MAX3232E-Q1
SLLS676A – DECEMBER 2005 – REVISED FEBRUARY 2008
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) (see Figure 3 )
PARAMETER TEST CONDITIONS
(1)
TYP
(2)
UNIT
t
PLH
Propagation delay time, low- to high-level output C
L
= 150 pF 300 ns
t
PHL
Propagation delay time, high- to low-level output C
L
= 150 pF 300 ns
t
sk(p)
Pulse skew
(3)
300 ns
(1) Test conditions are C1 – C4 = 0.1 µ F at V
CC
= 3.3 V ± 0.3 V; C1 = 0.047 µ F, C2 – C4 = 0.33 µ F at V
CC
= 5 V ± 0.5 V.
(2) All typical values are at V
CC
= 3.3 V or V
CC
= 5 V and T
A
= 25 ° C.
(3) Pulse skew is defined as |t
PLH
– t
PHL
| of each channel of the same device.
4 Submit Documentation Feedback Copyright © 2005 – 2008, Texas Instruments Incorporated
Product Folder Link(s): MAX3232E-Q1