Absolute Maximum Ratings
(1)
Recommended Operating Conditions
(1)
Electrical Characteristics
(1)
MAX3232E
3-V TO 5.5-V MULTICHANNEL RS-232 LINE DRIVER/RECEIVER
WITH ± 15-kV IEC ESD PROTECTION
SLLS664A AUGUST 2005 REVISED APRIL 2007
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
Supply voltage range
(2)
–0.3 6 V
V
+
Positive output supply voltage range
(2)
–0.3 7 V
V– Negative output supply voltage range
(2)
0.3 –7 V
V
+
Supply voltage difference
(2)
13 V
V–
Drivers –0.3 6 V
V
I
Input voltage range
Receivers –25 25 V
Drivers –13.2 13.2 V
V
O
Output voltage range
Receivers –0.3 V
CC
+ 0.3 V
D package 73
DB package 82
θ
JA
Package thermal impedance
(3) (4)
° C/W
DW package 57
PW package 108
T
J
Operating virtual junction temperature 150 ° C
T
stg
Storage temperature range –65 150 ° C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to network GND.
(3) Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) T
A
)/ θ
JA
. Operating at the absolute maximum T
J
of 150 ° C can affect reliability.
(4) The package thermal impedance is calculated in accordance with JESD 51-7.
See Figure 4
MIN NO MAX UNIT
M
V
CC
= 3.3 V 3 3.3 3.6
Supply voltage V
V
CC
= 5 V 4.5 5 5.5
V
CC
= 3.3 V 2 5.5
V
IH
Driver high-level input voltage DIN V
V
CC
= 5 V 2.4 5.5
V
IL
Driver low-level input voltage DIN 0 0.8 V
V
I
Receiver input voltage –25 25 V
MAX3232EC 0 70
T
A
Operating free-air temperature ° C
MAX3232EI –40 85
(1) Test conditions are C1–C4 = 0.1 µ F at V
CC
= 3.3 V ± 0.3 V; C1 = 0.047 µ F, C2–C4 = 0.33 µ F at V
CC
= 5 V ± 0.5 V.
over recommended ranges of supply voltage and operating free-air temperature (unless otherwise noted) (see Figure 4 )
PARAMETER TEST CONDITIONS MIN TYP
(2)
MAX UNIT
I
CC
Supply current No load, V
CC
= 3.3 V or 5 V 0.3 1 mA
(1) Test conditions are C1–C4 = 0.1 µ F at V
CC
= 3.3 V ± 0.3 V; C1 = 0.047 µ F, C2–C4 = 0.33 µ F at V
CC
= 5 V ± 0.5 V.
(2) All typical values are at V
CC
= 3.3 V or V
CC
= 5 V, and T
A
= 25 ° C.
3