Datasheet
±
SLLS409K − JANUARY 2000 − REVISED MARCH 2004
4
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
recommended operating conditions (see Note 4 and Figure 6)
MIN NOM MAX UNIT
Supply voltage
V
CC
= 3.3 V 3 3.3 3.6
V
Supply voltage
V
CC
= 5 V
4.5 5 5.5
V
V
IH
Driver and control high-level input voltage
DIN, EN, FORCEOFF,
V
CC
= 3.3 V 2
V
V
IH
Driver and control high-level input voltage
DIN, EN, FORCEOFF,
FORCEON
V
CC
= 5 V 2.4
V
V
IL
Driver and control low-level input voltage DIN, EN, FORCEOFF, FORCEON 0.8 V
V
I
Driver and control input voltage DIN, EN, FORCEOFF, FORCEON 0 5.5
V
V
I
Receiver input voltage −25 25
V
T
A
Operating free-air temperature
MAX3223C 0 70
°C
T
A
Operating free-air temperature
MAX3223I −40 85
°
C
NOTE 4: Test conditions are C1−C4 = 0.1 µF at V
CC
= 3.3 V ± 0.3 V; C1 = 0.047 µF, C2−C4 = 0.33 µF at V
CC
= 5 V ± 0.5 V.
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (see Note 4 and Figure 6)
PARAMETER TEST CONDITIONS MIN TYP
†
MAX UNIT
I
I
Input leakage
current
EN, FORCEOFF,
FORCEON
±0.01 ±1 µA
Auto-powerdown
disabled
V
CC
= 3.3 V or 5 V,
No load,
FORCEOFF
and
FORCEON at V
CC
0.3 1 mA
I
CC
Supply current
Powered off
V
CC
= 3.3 V or 5 V,
T
A
= 25
°
C
No load, FORCEOFF at GND 1 10
I
CC
Supply current
Auto-powerdown
enabled
T
A
= 25°C
No load, FORCEOFF at V
CC
,
FORCEON at GND,
All RIN are open or grounded
1 10
µA
†
All typical values are at V
CC
= 3.3 V or V
CC
= 5 V, and T
A
= 25°C.
NOTE 4: Test conditions are C1−C4 = 0.1 µF at V
CC
= 3.3 V ± 0.3 V; C1 = 0.047 µF, C2−C4 = 0.33 µF at V
CC
= 5 V ± 0.5 V.