Datasheet
±
SLLS590D − SEPTEMBER 2003 − REVISED AUGUST 2004
5
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
RECEIVER SECTION
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (see Note 4 and Figure 4)
PARAMETER TEST CONDITIONS MIN TYP
†
MAX UNIT
V
OH
High-level output voltage I
OH
= −1 mA 3.5 V
CC
− 0.2 V V
V
OL
Low-level output voltage I
OL
= 3.2 mA 0.4 V
V
IT+
Positive-going input threshold voltage V
CC
= 5 V 1.7 2.4 V
V
IT−
Negative-going input threshold voltage V
CC
= 5 V 0.8 1.3 V
V
hys
Input hysteresis (V
IT+
− V
IT−
) 0.2 0.5 1 V
r
i
Input resistance V
I
= ±3 V to ±25 V 3 5 7 kW
†
All typical values are at V
CC
= 5 V, and T
A
= 25°C.
NOTE 4: Test conditions are C1−C4 = 0.1 µF at V
CC
= 5 V ± 0.5 V.
switching characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (see Note 4 and Figure 3)
PARAMETER
TEST
CONDITIONS
MIN TYP
†
MAX UNIT
t
PLH
(R)
Propagation delay time, low- to high-level output C
L
= 150 pF 0.6 1 µs
t
PHL
(R)
Propagation delay time, high- to low-level output C
L
= 150 pF 0.5 1 µs
t
PHL
(R)
−
t
PLH
(R)
Receiver (+ to −) propagation delay difference 100 ns
t
sk(p)
Pulse skew
‡
100 ns
†
All typical values are at V
CC
= 5 V and T
A
= 25°C.
‡
Pulse skew is defined as |t
PLH
− t
PHL
| of each channel of the same device.
NOTE 4: Test conditions are C1−C4 = 0.1 µF, at V
CC
= 5 V ± 0.5 V.
ESD protection
PIN TEST CONDITIONS TYP UNIT
D
OUT
, R
IN