Datasheet
±
SLLS590D − SEPTEMBER 2003 − REVISED AUGUST 2004
3
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
†
Supply voltage range, V
CC
(see Note 1) −0.3 V to 6 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, V
I
: Drivers −0.3 V to V
CC
− 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Receivers ±30 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, V
O
: Drivers ±15 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Receivers −0.3 V to V
CC
+ 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Short-circuit duration, D
OUT
Continuous. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance,
θ
JA
(see Notes 2 and 3): DW package TBD°C/W. . . . . . . . . . . . . . . . . . . . . . . .
N package TBD°C/W. . . . . . . . . . . . . . . . . . . . . . . . . .
Operating virtual junction temperature, T
J
150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
†
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltages are with respect to network GND.
2. Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable
ambient temperature is P
D
= (T
J
(max) − T
A
)/θ
JA
. Operating at the absolute maximum T
J
of 150°C can affect reliability.
3. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions (see Note 4 and Figure 4)
MIN NOM MAX UNIT
V
CC
Supply voltage 4.5 5 5.5 V
V
IH
Driver high-level input voltage D
IN
2 V
V
IH
Shutdown high-level input voltage
SHDN
2 V
V
IL
Driver low-level input voltage D
IN
0.8 V
V
IL
Shutdown low-level input voltage
SHDN
0.8 V
V
I
Driver input voltage D
IN
0 5.5
V
V
I
Receiver input voltage −30 30
V
T
A
Operating free-air temperature
MAX222C 0 70
°C
T
A
Operating free-air temperature
MAX222I −40 85
°
C
NOTE 4: Test conditions are C1−C4 = 0.1 µF at V
CC
= 5 V ± 0.5 V.
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (see Note 4 and Figure 4)
PARAMETER TEST CONDITIONS MIN TYP MAX UNIT
I
CC
Supply current
V
CC
= 5 V
SHDN = V
CC
No load 4 10
mA
I
CC
Supply current V
CC
= 5 V
SHDN = V
CC
3 kW on both inputs 15
mA
Shutdown supply current 2 50 µA
SHDN
Shutdown input leakage current ±1 µA
NOTE 4: Test conditions are C1−C4 = 0.1 µF at V
CC