Datasheet
www.ti.com
Absolute Maximum Ratings
(1)
Recommended Operating Conditions
(1)
Electrical Characteristics
(1)
MAX213
5-V MULTICHANNEL RS-232 LINE DRIVER/RECEIVER
WITH ± 15-kV ESD PROTECTION
SLLS680 – DECEMBER 2005
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
Supply voltage range –0.3 6 V
V+ Positive charge-pump voltage range
(2)
V
CC
– 0.3 14 V
V– Negative charge-pump voltage range
(2)
0.3 –14 V
Drivers –0.3 V+ + 0.3
V
I
Input voltage range V
Receivers ± 30
Drivers V– – 0.3 V+ + 0.3
V
O
Output voltage range V
Receivers –0.3 V
CC
+ 0.3
DOUT Short-circuit duration Continuous
DB package 62
θ
JA
Package thermal impedance
(3) (4)
DW package 46 C ° /W
PW package
T
J
Operating virtual junction temperature 150 C °
T
stg
Storage temperature range –65 150 C °
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltages are with respect to network GND.
(3) Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) – T
A
)/ θ
JA
. Operating at the absolute maximum T
J
of 150 ° C can affect reliability.
(4) The package thermal impedance is calculated in accordance with JESD 51-7.
See Figure 4
MIN NOM MAX UNIT
Supply voltage 4.5 5 5.5 V
Driver high-level input voltage DIN 2
V
IH
V
Control high-level input voltage EN, SHDN 2.4
V
IL
Driver and control low-level input voltage DIN, EN, SHDN 0.8 V
Driver and control input voltage DIN, EN, SHDN 0 5.5
V
I
V
Receiver input voltage RIN –30 30
MAX213C 0 70
T
A
Operating free-air temperature ° C
MAX213I –40 85
(1) Test conditions are C1–C4 = 0.1 µ F at V
CC
= 5 V ± 0.5 V.
over operating free-air temperature range (unless otherwise noted)
PARAMETER TEST CONDITIONS MIN TYP
(2)
MAX UNIT
I
CC
Supply current No load, See Figure 6 14 20 mA
I
SHDN
Shutdown supply current T
A
= 25 ° C, See Figure 1 15 50 µ A
(1) Test conditions are C1–C4 = 0.1 µ F at V
CC
= 5 V ± 0.5 V.
(2) All typical values are at V
CC
= 5 V, and T
A
= 25 ° C.
4