Datasheet


    
 ±  
SLLS567E − MAY 2003 − REVISED JANUARY 2004
4
POST OFFICE BOX 655303 DALLAS, TEXAS 75265
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)
Supply voltage range, V
CC
(see Note 1) −0.3 V to 6 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Positive charge pump voltage range, V+ (see Note 1) V
CC
0.3 V to 14 V. . . . . . . . . . . . . . . . . . . . . . . . . . . .
Negative charge pump voltage range, V− (see Note 1) 0.3 V to −14 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Input voltage range, V
I
: Drivers −0.3 V to V+ + 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Receivers ±30 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Output voltage range, V
O
: Drivers V− 0.3 V to V+ + 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Receivers −0.3 V to V
CC
+ 0.3 V. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Short-circuit duration: DOUT Continuous. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Package thermal impedance, θ
JA
(see Notes 2 and 3): DB package 62°C/W. . . . . . . . . . . . . . . . . . . . . . . . . . .
DW package 46°C/W. . . . . . . . . . . . . . . . . . . . . . . . . .
Operating virtual junction temperature, T
J
150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Storage temperature range, T
stg
−65°C to 150°C. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and
functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not
implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltages are with respect to network GND.
2. Maximum power dissipation is a function of T
J
(max),
θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable
ambient temperature is P
D
= (T
J
(max) − T
A
)/
θ
JA
. Operating at the absolute maximum T
J
of 150°C can affect reliability.
3. The package thermal impedance is calculated in accordance with JESD 51-7.
recommended operating conditions (see Note 4 and Figure 4)
MIN NOM MAX UNIT
Supply voltage 4.5 5 5.5 V
V
IH
Driver high-level input voltage DIN 2
V
V
IH
Control high-level input voltage EN, SHDN 2.4
V
V
IL
Driver and control low-level input voltage DIN, EN, SHDN 0.8 V
V
I
Driver and control input voltage DIN, EN, SHDN 0 5.5
V
V
I
Receiver input voltage −30 30
V
T
A
MAX211C 0 70
°C
T
A
MAX211I −40 85
°
C
NOTE 4: Test conditions are C1−C4 = 0.1 µF at V
CC
= 5 V ± 0.5 V.
electrical characteristics over recommended ranges of supply voltage and operating free-air
temperature (unless otherwise noted) (see Note 4)
PARAMETER TEST CONDITIONS MIN TYP
MAX UNIT
I
CC
Supply current No load, See Figure 6 14 20 mA
Shutdown supply current T
A
= 25°C, See Figure 1 1 10 µA
All typical values are at V
CC
= 5 V, and T
A
= 25°C.
NOTE 4: Test conditions are C1−C4 = 0.1 µF at V
CC
= 5 V ± 0.5 V.