Datasheet
±
SLLS592B − OCTOBER 2003 − REVISED JANUARY 2004
7
POST OFFICE BOX 655303 • DALLAS, TEXAS 75265
APPLICATION INFORMATION
DOUT3
1
+
−
400 kΩ
5 V
18
DIN3
400 kΩ
5 V
19
400 kΩ
5 V
21
DOUT5
20
5 kΩ
23
ROUT2
22
RIN2
24
DOUT4
5 kΩ
16
ROUT3
17
RIN3
15
+−
C4 =
0.1 µF
16 V
14
13
+
−
C2 =
0.1 µF
16 V
C2−
C2+
DOUT1
2
400 kΩ
5 V
DIN1
7
400 kΩ
5 V
DIN2
6
DOUT2
3
RIN1
4
5 kΩ
ROUT1
5
C1 =
0.1 µF
6.3 V
12
11
V+
10
+
−
=
0.1 µF
6.3 V
9
V
CC
+
−
GND
8
DIN4
DIN5
C1+
C1−
V−
†
C3 can be connected to V
CC
or GND.
NOTES: A. Resistor values shown are nominal.
B. Nonpolarized ceramic capacitors are acceptable. If polarized tantalum or electrolytic capacitors are used, they should be
connected as shown.
C
BYPASS
= 0.1µF
C3
†
Figure 4. Typical Operating Circuit and Capacitor Values