Datasheet

Enable
Controller
Bias
Generator
Over
Current and
Thermal
Protection
LDO Core
and
Reference
V
IN
V
OUT
GND
EN
LP5951
www.ti.com
SNVS345F JUNE 2006REVISED MAY 2013
Output Capacitor, Recommended Specification
Symbol Parameter Conditions Value Limit
(1)
Units
Min Max
Capacitance
(2)
I
OUT
= 150mA, V
IN
= 5.0V 1.0 0.7 47 µF
C
OUT
Output Capacitance
ESR 0.003 0.300
(1) Min and Max limits are ensured by design
(2) The capacitor tolerance should be 30% or better over temperature. The full operating conditions for the application should be considered
when selecting a suitable capacitor to ensure that the minimum value of capacitance is always met. Recommended capacitor type is
X7R. However, dependent on application, X5R, Y5V, and Z5U can also be used. The shown minimum limit represents real minimum
capacitance, including all tolerances and must be maintained over temperature and dc bias voltage (See capacitor section in
Applications Hints)
Output Current Derating
Maximum Load Current vs V
IN
- V
OUT
, T
A
= 85°C, V
OUT
= 1.5V
Block Diagram
Copyright © 2006–2013, Texas Instruments Incorporated Submit Documentation Feedback 5
Product Folder Links: LP5951