Datasheet
LP38858
www.ti.com
SNVS462D –OCTOBER 2006–REVISED APRIL 2013
Figure 28. θ
JA
vs Copper (1 Ounce) Area for the DDPAK/TO-263 package
Figure 28 shows that increasing the copper area beyond 1 square inch produces very little improvement. The
minimum value for θ
JA
for the DDPAK/TO-263 package mounted to a PCB is 32°C/W.
Figure 29 shows the maximum allowable power dissipation for DDPAK/TO-263 packages for different ambient
temperatures, assuming θ
JA
is 35°C/W and the maximum junction temperature is 125°C.
Figure 29. Maximum Power Dissipation vs Ambient Temperature for the DDPAK/TO-263 Package
Copyright © 2006–2013, Texas Instruments Incorporated Submit Documentation Feedback 13
Product Folder Links: LP38858