Datasheet
LP3883
www.ti.com
SNVS223F –NOVEMBER 2002–REVISED APRIL 2013
θ
JA
= T
Rmax
/ P
D
(6)
These parts are available in TO-220 and DDPAK/TO-263 packages. The thermal resistance depends on amount
of copper area or heat sink, and on air flow. If the maximum allowable value of θ
JA
calculated above is ≥ 60 °C/W
for TO-220 package and ≥ 60 °C/W for DDPAK/TO-263 package no heatsink is needed since the package can
dissipate enough heat to satisfy these requirements. If the value for allowable θ
JA
falls below these limits, a heat
sink is required.
HEATSINKING TO-220 PACKAGE
The thermal resistance of a TO220 package can be reduced by attaching it to a heat sink or a copper plane on a
PC board. If a copper plane is to be used, the values of θ
JA
will be same as shown in next section for TO263
package.
The heatsink to be used in the application should have a heatsink to ambient thermal resistance,
θ
HA
≤ θ
JA
− θ
CH
− θ
JC
. (7)
In this equation, θ
CH
is the thermal resistance from the case to the surface of the heat sink and θ
JC
is the thermal
resistance from the junction to the surface of the case. θ
JC
is about 3°C/W for a TO220 package. The value for
θ
CH
depends on method of attachment, insulator, etc. θ
CH
varies between 1.5°C/W to 2.5°C/W. If the exact value
is unknown, 2°C/W can be assumed.
HEATSINKING DDPAK/TO-263 PACKAGE
The DDPAK/TO-263 package uses the copper plane on the PCB as a heatsink. The tab of these packages are
soldered to the copper plane for heat sinking. The graph below shows a curve for the θ
JA
of DDPAK/TO-263
package for different copper area sizes, using a typical PCB with 1 ounce copper and no solder mask over the
copper area for heat sinking.
Figure 34. θ
JA
vs Copper (1 Ounce) Area for DDPAK/TO-263 package
As shown in the graph below, increasing the copper area beyond 1 square inch produces very little improvement.
The minimum value for θ
JA
for the DDPAK/TO-263 package mounted to a PCB is 32°C/W.
Figure 35 shows the maximum allowable power dissipation for DDPAK/TO-263 packages for different ambient
temperatures, assuming θ
JA
is 35°C/W and the maximum junction temperature is 125°C.
Figure 35. Maximum power dissipation vs ambient temperature for DDPAK/TO-263 package
Copyright © 2002–2013, Texas Instruments Incorporated Submit Documentation Feedback 11
Product Folder Links: LP3883