Datasheet

www.ti.com
Enable Function
Figure 1. 10 mA to 3A Load Transient Response
Figure 2. 1A to 3A Load Transient Response
6 Enable Function
ON/OFF control is provided by supplying a logic level signal to the Enable pin. A minimum V
EN
value of
1.2V is typically required at this pin to enable the LDO output. The LDO output will be shutdown when the
V
EN
value is typically 0.6V or less. The V
EN
threshold incorporates approximately 100 mV of hysteresis.
3
SNVA264BJanuary 2009Revised April 2013 AN-1670 LP38513TJ-ADJ Evaluation Board
Submit Documentation Feedback
Copyright © 2009–2013, Texas Instruments Incorporated