Datasheet

www.ti.com
V
CC
OUT
IN−
IN+
Absolute Maximum Ratings
(1)
ESD Protection
LP324, LP2902
ULTRA-LOW-POWER QUADRUPLE OPERATIONAL AMPLIFIERS
SLOS460A MARCH 2005 REVISED MAY 2005
SCHEMATIC (EACH AMPLIFIER)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
Supply voltage range
(2)
± 16 or 32 V
V
ID
Differential input voltage
(3)
± 32 V
V
I
Input voltage (either input) –0.3 32 V
Duration of output short circuit (one amplifier) to ground at (or below) T
A
= 25 ° C, V
CC
15 V
(4)
Unlimited
D package 86
θ
JA
Package thermal impedance
(5) (6)
N package 80 ° C/W
PW package 113
T
J
Operating virtual junction temperature 150 ° C
T
stg
Storage temperature range –65 150 ° C
(1) Stresses beyond those listed under "absolute maximum ratings" may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under "recommended operating
conditions" is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values (except differential voltages and V
CC
specified for the measurement of I
OS
) are with respect to the network GND.
(3) Differential voltages are at IN+, with respect to IN–.
(4) Short circuits from outputs to V
CC
can cause excessive heating and eventual destruction.
(5) Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) T
A
)/ θ
JA
. Operating at the absolute maximum T
J
of 150 ° C can affect reliability.
(6) The package thermal impedance is calculated in accordance with JESD 51-7.
TEST CONDITIONS TYP UNIT
Human-Body Model ± 2 kV
2