Datasheet
20
30
40
50
60
70
80
90
0 0.05 0.1 0.15 0.2 0.25 0.3
Output Current (A)
Ambient Temperature (°C)
Natural Convection
V
O
= –12 V
G000
20
30
40
50
60
70
80
90
0 0.05 0.1 0.15 0.2 0.25
Output Current (A)
Ambient Temperature (°C)
Natural Convection
V
O
= –15 V
G000
0
0.5
1
1.5
2
2.5
0 0.2 0.4 0.6 0.8 1
Output Current (A)
Power Dissipation (W)
V
O
= –15 V, f
sw
= 800 kHz
V
O
= –12 V, f
sw
= 800 kHz
V
O
= –5.0 V, f
sw
= 800 kHz
V
O
= –3.3 V, f
sw
= 800 kHz
G000
20
30
40
50
60
70
80
90
0 0.1 0.2 0.3 0.4 0.5 0.6
Output Current (A)
Ambient Temperature (°C)
Natural Convection
V
O
= –5 V
G000
50
55
60
65
70
75
80
85
90
95
100
0 0.2 0.4 0.6 0.8 1
Output Current (A)
Efficiency (%)
V
O
= –15 V, f
sw
= 800 kHz
V
O
= –12 V, f
sw
= 800 kHz
V
O
= –5.0 V, f
sw
= 800 kHz
V
O
= –3.3 V, f
sw
= 800 kHz
G000
0
5
10
15
20
25
30
35
40
45
50
0 0.2 0.4 0.6 0.8 1
Output Current (A)
Output Voltage Ripple (mV)
V
O
= –15 V, f
sw
= 800 kHz
V
O
= –12 V, f
sw
= 800 kHz
V
O
= –5.0 V, f
sw
= 800 kHz
V
O
= –3.3 V, f
sw
= 800 kHz
G000
LMZ34002
www.ti.com
SNVS989A –JULY 2013–REVISED SEPT 2013
TYPICAL CHARACTERISTICS (VIN = 5 V)
(1) (2)
Figure 1. Efficiency vs. Output Current Figure 2. Voltage Ripple vs. Output Current
Figure 3. Power Dissipation vs. Output Current Figure 4. Safe Operating Area
Figure 5. Safe Operating Area Figure 6. Safe Operating Area
(1) The electrical characteristic data has been developed from actual products tested at 25°C. This data is considered typical for the
converter. Applies to Figure 1, Figure 2, and Figure 3.
(2) The temperature derating curves represent the conditions at which internal components are at or below the manufacturer's maximum
operating temperatures. Derating limits apply to devices soldered directly to a 100 mm × 100 mm, 4-layer, double-sided PCB with 1 oz.
copper. Applies to Figure 4, Figure 5, and Figure 6.
Copyright © 2013, Texas Instruments Incorporated Submit Documentation Feedback 7
Product Folder Links: LMZ34002