Slow Start (SS/TR)
Connecting the STSEL pin to AGND and leaving SS/TR pin open enables the internal SS capacitor with a slow
start interval of approximately 1.1 ms. Adding additional capacitance between the SS pin and AGND increases
the slow start time. Table 6 shows an additional SS capacitor connected to the SS/TR pin and the STSEL pin
connected to AGND. See Table 6 below for SS capacitor values and timing interval.
Figure 32. Slow-Start Capacitor (C
SS
) and STSEL Connection
Table 6. Slow-Start Capacitor Values and Slow-Start Time
C
SS
(pF) open 2200 4700 10000 15000 22000 25000
SS Time (msec) 1.1 1.9 2.8 4.6 6.4 8.8 9.8
Overcurrent Protection
For protection against load faults, the LMZ31506 incorporates output overcurrent protection. Applying a load that
exceeds the regulator's overcurrent threshold causes the regulated output to shut down. Following shutdown, the
module periodically attempts to recover by initiating a soft-start power-up as shown in Figure 33. This is
described as a hiccup mode of operation, whereby the module continues in a cycle of successive shutdown and
power up until the load fault is removed. During this period, the average current flowing into the fault is
significantly reduced. Once the fault is removed, the module automatically recovers and returns to normal
operation as shown in Figure 34.
Figure 33. Overcurrent Limiting Figure 34. Removal of Overcurrent Condition