Datasheet

VOLTAGE
TIME
RATIOMETRIC STARTUP
V
OUT2
EN
V
OUT1
R
trkb
=
R
trkt
V
OUT1
-1.0V
VIN
EN
GND
SS
R
trkb
R
trkt
V
IN
C
in1
Master Power
Supply
V
OUT1
V
OUT2
C
O1
V
SS
LMZ10505EXT
VOUT
LMZ10505EXT
www.ti.com
SNVS669G JUNE 2010REVISED OCTOBER 2013
where V
FB
is the internal reference voltage (nominally 0.8V), I
SS
is the soft-start charging current (nominally 2 µA)
and C
SS
is the external soft-start capacitance.
Thus, the required soft-start capacitor per unit output voltage startup time is given by
C
SS
= 2.5 nF / ms (21)
For example, a 4 ms soft-start time will yield a 10 nF capacitance. The minimum soft-start capacitance is 680 pF.
TRACKING
The LMZ10505EXT can track the output of a master power supply during soft-start by connecting a resistor
divider to the SS pin. In this way, the output voltage slew rate of the LMZ10505EXT will be controlled by a
master supply for loads that require precise sequencing. When the tracking function is used, a small value soft-
start capacitor should be connected to the SS pin to alleviate output voltage overshoot when recovering from a
current limit fault.
TRACKING - EQUAL SOFT-START TIME
One way to use the tracking feature is to design the tracking resistor divider so that the master supply output
voltage, V
OUT1
, and the LMZ10505EXT output voltage, V
OUT2
, both rise together and reach their target values at
the same time. This is termed ratiometric startup. For this case, the equation governing the values of tracking
divider resistors R
trkb
and R
trkt
is given by
(22)
The above equation includes an offset voltage, of 200 mV, to ensure that the final value of the SS pin voltage
exceeds the reference voltage of the LMZ10505EXT. This offset will cause the LMZ10505EXT output voltage to
reach regulation slightly before the master supply. A value of 33 k 1% is recommended for R
trkt
as a
compromise between high precision and low quiescent current through the divider while minimizing the effect of
the 2 µA soft-start current source.
For example, if the master supply voltage V
OUT1
is 3.3V and the LMZ10505EXT output voltage was 1.8V, then
the value of R
trkb
needed to give the two supplies identical soft-start times would be 14.3 k. A timing diagram for
this example, the equal soft-start time case, is shown below.
Copyright © 2010–2013, Texas Instruments Incorporated Submit Documentation Feedback 15
Product Folder Links: LMZ10505EXT