Datasheet
LMV331-Q1 SINGLE, LMV393-Q1 DUAL
www.ti.com
SLOS468D – MAY 2005– REVISED AUGUST 2011
Electrical Characteristics
at specified free-air temperature, V
CC+
= 5 V, GND = 0 V (unless otherwise noted)
PARAMETER TEST CONDITIONS T
A
MIN TYP MAX UNIT
25°C 1.7 7
V
IO
Input offset voltage mV
–40°C to 125°C 9
Average temperature coefficient
αV
IO
25°C 5 μV/°C
of input offset voltage
25°C 25 250
I
IB
Input bias current nA
–40°C to 125°C 400
25°C 2 50
I
IO
Input offset current nA
–40°C to 125°C 150
I
O
Output current (sinking) V
O
≤ 1.5 V 25°C 10 84 mA
25°C 0.003
Output leakage current μA
–40°C to 125°C 1
–0.1
V
ICR
Common-mode input voltage range 25°C V
to 4.2
A
VD
Large-signal differential voltage gain 25°C 20 50 V/mV
25°C 200 400
V
SAT
Saturation voltage I
O
≤ 4 mA mV
–40°C to 125°C 700
25°C 60 120
LMV331
–40°C to 125°C 150
25°C 100 200
I
CC
Supply current LMV393 (both comparators) μA
–40°C to 125°C 250
25°C 170 300
LMV339 (all four comparators)
–40°C to 125°C 350
Switching Characteristics
T
A
= 25°C, V
CC+
= 5 V, R
L
= 5.1 kΩ, GND = 0 V (unless otherwise noted)
PARAMETER TEST CONDITIONS TYP UNIT
Input overdrive = 10 mV 600
t
PHL
Propagation delay, high- to low-level output switching ns
Input overdrive = 100 mV 200
Input overdrive = 10 mV 450
t
PLH
Propagation delay, low- to high-level output switching ns
Input overdrive = 100 mV 300
Copyright © 2005–2011, Texas Instruments Incorporated 5