Datasheet

LMV331-Q1 SINGLE, LMV393-Q1 DUAL
www.ti.com
SLOS468D MAY 2005 REVISED AUGUST 2011
Absolute Maximum Ratings
(1)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC+
Supply voltage
(2)
5.5 V
V
ID
Differential input voltage
(3)
±5.5 V
V
I
Input voltage range (either input) 0 5.5 V
D (8-pin) package 97
θ
JA
Package thermal impedance
(4) (5)
D (14-pin) package 86 °C/W
DBV package 206
T
J
Operating virtual junction temperature 150 °C
T
stg
Storage temperature range 65 150 °C
(1) Stresses beyond those listed under absolute maximum ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under recommended operating
conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values (except differential voltages and V
CC+
specified for the measurement of I
OS
) are with respect to the network GND.
(3) Differential voltages are at IN+ with respect to IN.
(4) Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) T
A
)/θ
JA
. Selecting the maximum of 150°C can affect reliability.
(5) The package thermal impedance is calculated in accordance with JESD 51-7.
Recommended Operating Conditions
MIN MAX UNIT
V
CC+
Supply voltage (single-supply operation) 2.7 5.5 V
V
OUT
Output voltage V
CC+
+ 0.3 V
T
A
Operating free-air temperature 40 125 °C
Copyright © 20052011, Texas Instruments Incorporated 3