Datasheet

LMV331 SINGLE
LMV393 DUAL
LMV339 QUAD
www.ti.com
SLCS136S AUGUST 1999REVISED OCTOBER 2012
Absolute Maximum Ratings
(1)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
Supply voltage
(2)
5.5 V
V
ID
Differential input voltage
(3)
±5.5 V
V
I
Input voltage range (either input) 0 V
CC+
V
At or below T
A
= 25°C,
Duration of output short circuit (one amplifier) to ground
(4)
Unlimited
V
CC
5.5 V
8 pin 97
D package
14 pin 86
DBV package 206
DCK package 252
θ
JA
Package thermal impedance
(5) (6)
DDU package 210 °C/W
RUC package 216
DGK package 172
8 pin 149
PW package
14 pin 113
T
J
Operating virtual junction temperature 150 °C
T
stg
Storage temperature range –65 150 °C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values (except differential voltages and V
CC
specified for the measurement of I
OS
) are with respect to the network GND.
(3) Differential voltages are at IN+ with respect to IN–.
(4) Short circuits from outputs to V
CC
can cause excessive heating and eventual destruction.
(5) Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) – T
A
)/θ
JA
. Operating at the absolute maximum T
J
of 150°C can affect reliability.
(6) The package thermal impedance is calculated in accordance with JESD 51-7.
Recommended Operating Conditions
MIN MAX UNIT
V
CC
Supply voltage (single-supply operation) 2.7 5.5 V
V
CC+
+
V
OUT
Output voltage V
0.3
T
A
Operating free-air temperature I temperature –40 125 °C
Copyright © 1999–2012, Texas Instruments Incorporated Submit Documentation Feedback 3