Datasheet

LMV321 SINGLE, LMV358 DUAL
LMV324 QUAD, LMV324S QUAD WITH SHUTDOWN
SLOS263U AUGUST 1999REVISED JULY 2012
www.ti.com
Absolute Maximum Ratings
(1)
over operating free-air temperature range (unless otherwise noted)
MIN MAX UNIT
V
CC
Supply voltage
(2)
5.5 V
V
ID
Differential input voltage
(3)
±5.5 V
V
I
Input voltage range (either input) –0.2 5.5 V
At or below T
A
= 25°C,
Duration of output short circuit (one amplifier) to ground
(4)
Unlimited
V
CC
5.5 V
8 pin 97
D package 14 pin 86
16 pin 73
DBV package 5 pin 206
DCK package 5 pin 252
θ
JA
Package thermal impedance
(5) (6)
°C/W
DDU package 8 pin 210
DGK package 8 pin 172
8 pin 149
PW package 14 pin 113
16 pin 108
T
J
Operating virtual junction temperature 150 °C
T
stg
Storage temperature range –65 150 °C
(1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings
only, and functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating
Conditions is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
(2) All voltage values (except differential voltages and V
CC
specified for the measurement of I
OS
) are with respect to the network GND.
(3) Differential voltages are at IN+ with respect to IN–.
(4) Short circuits from outputs to V
CC
can cause excessive heating and eventual destruction.
(5) Maximum power dissipation is a function of T
J
(max), θ
JA
, and T
A
. The maximum allowable power dissipation at any allowable ambient
temperature is P
D
= (T
J
(max) – T
A
)/θ
JA
. Operating at the absolute maximum T
J
of 150°C can affect reliability.
(6) The package thermal impedance is calculated in accordance with JESD 51-7.
Recommended Operating Conditions
(1)
MIN MAX UNIT
V
CC
Supply voltage (single-supply operation) 2.7 5.5 V
V
CC
= 2.7 V 1.7
V
IH
Amplifier turn-on voltage level (LMV324S)
(2)
V
V
CC
= 5 V 3.5
V
CC
= 2.7 V 0.7
V
IL
Amplifier turn-off voltage level (LMV324S) V
V
CC
= 5 V 1.5
I temperature (LMV321,
–40 125
LMV358, LMV324)
T
A
Operating free-air temperature I temperature (LMV324S, °C
-40 85
LMV321IDCK)
Q temperature –40 125
(1) All unused control inputs of the device must be held at V
CC
or GND to ensure proper device operation. See the TI application report,
Implications of Slow or Floating CMOS Inputs, literature number SCBA004.
(2) V
IH
should not be allowed to exceed V
CC
.
4 Submit Documentation Feedback Copyright © 1999–2012, Texas Instruments Incorporated