Datasheet
LMP92001
www.ti.com
SNAS507B –FEBRUARY 2011–REVISED APRIL 2012
Bx Name Function
0 - RESERVED, must be 1
DATA REGISTERS
All registers in this section require 16-bit I
2
C-compatible data transaction for both read and write operations.
However, only lower 12 bits are stored. All data is assumed to be in the unsigned binary format, where the
lowest value is represented by 0x000 and the highest value is represented by 0xFFF.
ADC Output Data Register: ADCx[15:0], default 0x0000
The ADCx registers, x = 1...16, contain results of the most recent ADC conversion cycle. Accessing these
registers does not preempt the Analog Sense Subsystem sequencing. Enabling/Disabling of the ADC input
channels via CADx registers does not affect the ADCx content.
Bx Name Function
15:12 - Always 0
11:0 - 12-bit binary representing the ADC conversion result
ADC High-Limit Register: LIHx[15:0], default 0x0FFF
The LILx registers, x=1...3 and 9...11, contain the HIGH LIMIT threshold of the window comparator function of
the Analog Sense Subsystem.
Bx Name Function
15:12 - Always 0. Data written to this location will be discarded.
11:0 - Window comparator upper limit.
ADC Low-Limit Register: LILx[15:0], default 0x0000
The LILx registers, x=1...3 and 9...11, contain the LOW LIMIT threshold of the window comparator function of the
Analog Sense Subsystem.
Bx Name Function
15:12 - Always 0. Data written to this location will be discarded.
11:0 - Window comparator lower limit.
DAC Data Register: DACx[15:0], default 0x0000
The DACx registers, x=1...12, are input code registers. Updating the DACx register automatically updates the
VOUTx of the corresponding DAC. Note that OUTx may not update due to the state of the asynchronous control
inputs C[1:4]. (See Asynchronous Output Control.)
Bx Name Function
15:12 - Always 0. Data written to this location will be discarded.
11:0 - DACx input data.
Write all DAC's Data Register: DALL[15:0], default 0x0000
Writing to this register updates all DACx registers simultaneously to this value. Note that OUTx may not update
due to the state of the asynchronous control inputs C[1:4].
Bx Name Function
15:12 - Always 0. Data written to this location will be discarded.
11:0 - DAC input data.
Copyright © 2011–2012, Texas Instruments Incorporated Submit Documentation Feedback 19
Product Folder Links: LMP92001