Datasheet
LMP90100
SNAS510P –JANUARY 2011–REVISED MARCH 2013
www.ti.com
Table 13. ADC_DONE: ADC Data Available (Address 0x18)
Bit Bit Symbol Bit Description
Data Available – indicates if new conversion data is available
[7:0] DT_AVAIL_B 0x00 − 0xFE: Available
0xFF: Not available
Table 14. ADC_DOUT: 24-bit Conversion Data (two’s complement) (Address 0x1A - 0x1C)
Address Name Register Description
0x1A ADC_DOUTH ADC Conversion Data [23:16]
0x1B ADC_DOUTM ADC Conversion Data [15:8]
0x1C ADC_DOUTL ADC Conversion Data [7:0]
Note: Repeat reads of these registers are allowed as long as such reads are spaced apart by at least 72 µs.
CHANNEL CONFIGURATION REGISTERS
Table 15. CH_STS: Channel Status (Address 0x1E)
Bit Bit Symbol Bit Description
[7:2] Reserved -
Channel Scan Not Ready – indicates if it is okay to program CH_SCAN
1 CH_SCAN_NRDY 0: Update not pending, CH_SCAN register is okay to program
1: Update pending, CH_SCAN register is not ready to be programmed
Invalid or Repeated Read Status
0 INV_OR_RPT_RD_STS 0: ADC_DOUT just read was valid and hitherto unread
1: ADC_DOUT just read was either invalid (not ready) or there was a repeated read.
Table 16. CH_SCAN: Channel Scan Mode (Address 0x1F)
Bit Bit Symbol Bit Description
Channel Scan Select
0x0 (default): ScanMode0: Single-Channel Continuous Conversion
[7:6] CH_SCAN_SEL 0x1: ScanMode1: One or more channels Single Scan
0x2: ScanMode2: One or more channels Continuous Scan
0x3: ScanMode3: One or more channels Continuous Scan with Burnout Currents
Last channel for conversion
0x0: CH0
0x1: CH1
0x2: CH2
LAST_CH
0x3: CH3
[5:3] (CH4 to CH6 for LMP90100 and
0x4: CH4
LMP90099 only)
0x5: CH5
0x6 (default): CH6
Note: LAST_CH cannot be smaller than FIRST_CH. For example, if LAST_CH = CH5, then
FIRST_CH cannot be CH6. If 0x7 is written it is ignored.
56 Submit Documentation Feedback Copyright © 2011–2013, Texas Instruments Incorporated
Product Folder Links: LMP90100