• True Continuous Background Calibration
The LMP90100/LMP90099/LMP90098/LMP90097 feature a 24 bit ΣΔ core with continuous background
calibration to compensate for gain and offset errors in the ADC, virtually eliminating any drift with time and
temperature. The calibration is performed in the background without user or ADC input interruption, making it
unique in the industry and eliminating down time associated with field calibration required with other solutions.
Having this continuous calibration improves performance over the entire life span of the end product.
• Continuous Background Sensor Diagnostics
Sensor diagnostics are also performed in the background, without interfering with signal path performance,
allowing the detection of sensor shorts, opens, and out-of-range signals, which vastly improves system reliability.
In addition, the fully flexible input multiplexer described below allows any input pin to be connected to any ADC
input channel providing additional sensor path diagnostic capability.
• Flexible Input MUX Channels
The flexible input MUX allows interfacing to a wide range of sensors such as thermocouples, RTDs, thermistors,
and bridge sensors. The LMP90100/LMP90099’s multiplexer supports 4 differential channels while the
LMP90098/LMP90097 supports 2. Each effective input voltage that is digitized is VIN = VINx VINy, where x
and y are any input. In addition, the input multiplexer of the LMP90100/LMP90099 also supports 7 single-ended
channels (LMP90098/LMP90097 supports 4), where the common ground is any one of the inputs.
• Programmable Gain Amplifiers (FGA & PGA)
The LMP90100/LMP90099/LMP90098/LMP90097 contain an internal 16x fixed gain amplifier (FGA) and a 1x,
2x, 4x, or 8x programmable gain amplifier (PGA). This allows accurate gain settings of 1x, 2x, 4x, 8x, 16x, 32x,
64x, or 128x through configuration of internal registers. Having an internal amplifier eliminates the need for
external amplifiers that are costly, space consuming, and difficult to calibrate.
• Excitation Current Sources (IB1 & IB2) - LMP90100/LMP90098
Two matched internal excitation currents, IB1 and IB2, can be used for sourcing currents to a variety of sensors.
The current range is from 100 µA to 1000 µA in steps of 100 µA.