Datasheet

SCLK
SDO
t
DOD2
0.7V
IO
0.9V
IO
0.1V
IO
DB0
SCLK
SDO
0.1 V
IO
0.3 V
IO
0.9 V
IO
DB0
t
DOD2
(optional,
SW_OFF_TRG = 1)
SCLK
SDO
DB
DB
0.3V
IO
0.7V
IO
t
DOH
t
DOA
0.7V
IO
0.3V
IO
0.3V
IO
SCLK
SDI
DB
0.3V
IO
0.7V
IO
0.3V
IO
0.7V
IO
0.7V
IO
t
DIH
t
DISU
SCLK
0.9V
IO
0.1V
IO
t
CLKF
t
CLKR
0.1V
IO
0.9V
IO
LMP90100
SNAS510P JANUARY 2011REVISED MARCH 2013
www.ti.com
Symbol Parameter Conditions Min Typical Max Units
t
CLKR
SCLK Rise time 1.15 ns
t
CLKF
SCLK Fall time 1.15 ns
SDI Setup time prior to an SCLK
5 ns
t
DISU
rising edge
SDI Hold time after an SCLK rising
6 ns
t
DIH
edge
Symbol Parameter Conditions Min Typical Max Units
SDO Access time after an SCLK
t
DOA
35 ns
falling edge
SDO Hold time after an SCLK
t
DOH
5 ns
falling edge
SDO Disable time after the rising
t
DOD1
5 ns
edge of CSB
Symbol Parameter Conditions Min Typical Max Units
SDO Disable time after either edge
t
DOD2
27 ns
of SCLK
14 Submit Documentation Feedback Copyright © 2011–2013, Texas Instruments Incorporated
Product Folder Links: LMP90100