7. Step 7: Set Calibration - click on the “No Calibrationblock to enable or disable calibration.
Refer to the LMP90100 datasheet to more information on the LMP90100’s background
calibration types and modes. (For this exercise, the calibration can be OFF).
8. Step 8: Int/Ext CLK? – click on the “CLK MUX” block and make sure the internal clock is
selected.
9. Step 9: Performance - click on the Performance” mini-tab. This tab displays the Estimated
Device Performance base on the block diagram that you’ve configured, as well as the
Measured System Performance if you’ve connected a board and ran the LMP90100.
F. Capturing Data
1. Click on the “Measurement” tab and set the “Scan Mode” as follows:
Figure 17 - Scan Mode Settings
2. Under the “Output Format” field, select Display “Temperature (°C ) ”
3. Make sure the “Sensor Characteristics” is set as:
4. Under the “Stop Condition” field, select “Run Continuously”.
5. Click on the “Run” button to view the output temperature reading. A reading of
approximately 23°C to 25°C (room temperature) should be plotted.