Datasheet

0 12 24 36 48 60 72 84 96 108 120
-120
-100
-80
-60
-40
-20
0
GAIN (dB)
FREQUENCY (Hz)
6.71 SPS
13.42 SPS
0 12 24 36 48 60 72 84 96 108 120
-120
-100
-80
-60
-40
-20
0
GAIN (dB)
FREQUENCY (Hz)
1.6775 SPS
3.355 SPS
LMP90077, LMP90078, LMP90079, LMP90080
SNAS521F JULY 2011REVISED MARCH 2013
www.ti.com
Note that these ODRs are meant for a single channel conversion; the ODR needs to be divided by n for n
channels scanning. For example, if the ADC were running at 214.65 SPS and four channels are being scanned,
then the ODR per channel would be 214.65/4 = 53.6625 SPS.
Digital Filter
The LMP900xx has a fourth order rotated sinc filter that is used to configure various ODRs and to reject power
supply frequencies of 50Hz and 60Hz. The 50/60 Hz rejection is only effective when the device is operating at
ODR 13.42 SPS. If the internal CLK or the external CLK of 3.5717 MHz is used, then the LMP900xx will have
the frequency response shown in Figure 33 through Figure 37.
Figure 33. Digital Filter Response, 1.6775 SPS and 3.355 SPS
Figure 34. Digital Filter Response, 6.71 SPS and 13.42 SPS
22 Submit Documentation Feedback Copyright © 2011–2013, Texas Instruments Incorporated
Product Folder Links: LMP90077 LMP90078 LMP90079 LMP90080