Datasheet
Table Of Contents

LMP7715, LMP7716, LMP7716Q
www.ti.com
SNOSAV0E –MARCH 2006–REVISED MARCH 2013
2.5V Electrical Characteristics
Unless otherwise specified, all limits are ensured for T
A
= 25°C, V
+
= 2.5V, V
−
= 0V ,V
O
= V
CM
= V
+
/2. Boldface limits apply at
the temperature extremes.
Symbol Parameter Conditions Min
(1)
Typ
(2)
Max
(1)
Units
V
OS
±20 ±180
−20°C ≤ T
A
≤ 85°C
±330
Input Offset Voltage μV
±20 ±180
−40°C ≤ T
A
≤ 125°C
±430
TC V
OS
Input Offset Voltage Temperature LMP7715 -1 ±4
μV/°C
Drift
(3)(4)
LMP7716/LMP7716Q -1.75
I
B
−40°C ≤ T
A
≤ 85°C 0.05 1
25
Input Bias Current V
CM
= 1.0V
(4)(5)
pA
−40°C ≤ T
A
≤ 125°C 0.05 1
100
I
OS
0.006 0.5
Input Offset Current V
CM
= 1V
(4)
pA
50
83 100
CMRR Common Mode Rejection Ratio 0V ≤ V
CM
≤ 1.4V dB
80
PSRR 2.0V ≤ V
+
≤ 5.5V 85 100
V
−
= 0V, V
CM
= 0 80
Power Supply Rejection Ratio dB
1.8V ≤ V
+
≤ 5.5V 85 98
V
−
= 0V, V
CM
= 0
CMVR CMRR ≥ 80 dB −0.3 1.5
Common Mode Voltage Range V
CMRR ≥ 78 dB –0.3 1.5
A
VOL
LMP7715, V
O
= 0.15 to 2.2V 88 98
R
L
= 2 kΩ to V
+
/2 82
LMP7716/LMP7716Q, V
O
= 0.15 to 2.2V 84 92
R
L
= 2 kΩ to V
+
/2 80
Open Loop Voltage Gain dB
LMP7715, V
O
= 0.15 to 2.2V 92 110
R
L
= 10 kΩ to V
+
/2 88
LMP7716/ LMP7716Q, V
O
= 0.15 to 2.2V 90 95
R
L
= 10 kΩ to V
+
/2 86
V
OUT
25 70
R
L
= 2 kΩ to V
+
/2
77
Output Voltage Swing
High
20 60 mV from
R
L
= 10 kΩ to V
+
/2
66 either rail
30 70
R
L
= 2 kΩ to V
+
/2
73
Output Voltage Swing
Low
15 60
R
L
= 10 kΩ to V
+
/2
62
I
OUT
Sourcing to V
−
36 52
V
IN
= 200 mV
(6)
30
Output Current mA
Sinking to V
+
7.5 15
V
IN
= −200 mV
(6)
5.0
I
S
0.95 1.30
LMP7715
1.65
Supply Current mA
1.10 1.50
LMP7716/LMP7716Q (per channel)
1.85
SR A
V
= +1, Rising (10% to 90%) 8.3
Slew Rate V/μs
A
V
= +1, Falling (90% to 10%) 10.3
(1) Limits are 100% production tested at 25°C. Limits over the operating temperature range are specified through correlations using the
Statistical Quality Control (SQC) method.
(2) Typical values represent the most likely parametric norm as determined at the time of characterization. Actual typical values may vary
over time and will also depend on the application and configuration. The typical values are not tested and are not specified on shipped
production material.
(3) Offset voltage average drift is determined by dividing the change in V
OS
at the temperature extremes by the total temperature change.
(4) This parameter is specified by design and/or characterization and is not tested in production.
(5) Positive current corresponds to current flowing into the device.
(6) The short circuit test is a momentary open loop test.
Copyright © 2006–2013, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Links: LMP7715 LMP7716 LMP7716Q