Datasheet

LMP2014MT
www.ti.com
SNOSAK6B DECEMBER 2004REVISED MARCH 2013
2.7V DC Electrical Characteristics (continued)
Unless otherwise specified, all limits specified for T
J
= 25°C, V
+
= 2.7V, V
-
= 0V, V
CM
= 1.35V, V
O
= 1.35V and R
L
> 1 MΩ.
Boldface limits apply at the temperature extremes.
Symbol Parameter Conditions Min
(1)
Typ
(2)
Max
(1)
Units
V
O
Output Swing R
L
= 10 k to 1.35V 2.63 2.68
V
IN
(diff) = ±0.5V 2.655
V
0.033 0.070
0.075
R
L
= 2 k to 1.35V 2.615 2.65
V
IN
(diff) = ±0.5V 2.615
V
0.061 0.085
0.105
I
O
Output Current Sourcing, V
O
= 0V 5 12
V
IN
(diff) = ±0.5V 3
mA
Sinking, V
O
= 5V 5 18
V
IN
(diff) = ±0.5V 3
I
S
Supply Current per Channel 0.919 1.20 mA
1.50
2.7V AC Electrical Characteristics
T
J
= 25°C, V
+
= 2.7V, V
-
= 0V, V
CM
= 1.35V, V
O
= 1.35V, and R
L
> 1 MΩ. Boldface limits apply at the temperature extremes.
Symbol Parameter Conditions Min
(1)
Typ
(2)
Max
(1)
Units
GBW Gain-Bandwidth Product 3 MHz
SR Slew Rate 4 V/μs
θ
m
Phase Margin 60 Deg
G
m
Gain Margin 14 dB
e
n
Input-Referred Voltage Noise 35 nV/Hz
i
n
Input-Referred Current Noise pA/Hz
e
n
p-p Input-Referred Voltage Noise R
S
= 100, DC to 10 Hz 850 nV
pp
t
rec
Input Overload Recovery Time 50 ms
(1) Limits are 100% production tested at 25°C. Limits over the operating temperature range are specified through correlations using
statistical quality control (SQC) method.
(2) Typical values represent the most likely parametric norm.
5V DC Electrical Characteristics
Unless otherwise specified, all limits specified for T
J
= 25°C, V
+
= 5V, V
-
= 0V, V
CM
= 2.5V, V
O
= 2.5V and R
L
> 1MΩ.
Boldface limits apply at the temperature extremes.
Symbol Parameter Conditions Min
(1)
Typ
(2)
Max
(1)
Units
V
OS
Input Offset Voltage 0.12 30 μV
60
Offset Calibration Time 0.5 10 ms
12
TCV
OS
Input Offset Voltage 0.015 μV/°C
Long-Term Offset Drift 0.006 μV/month
Lifetime V
OS
Drift 2.5 μV
I
IN
Input Current -3 pA
I
OS
Input Offset Current 6 pA
R
IND
Input Differential Resistance 9 M
CMRR Common Mode Rejection Ratio 0.3 V
CM
3.2 100 130 dB
0 V
CM
3.2 90
(1) Limits are 100% production tested at 25°C. Limits over the operating temperature range are specified through correlations using
statistical quality control (SQC) method.
(2) Typical values represent the most likely parametric norm.
Copyright © 2004–2013, Texas Instruments Incorporated Submit Documentation Feedback 3
Product Folder Links: LMP2014MT