Datasheet
L M K 0 4 8 X X E V A L U A T I O N B O A R D O P E R A T I N G I N S T R U C T I O N S
7
Example: Using CodeLoader to Program the LMK04808B
The purpose of this section is to walk the user through using CodeLoader 4 to make some
measurements with the LMK04808B device as an example. For more information on
CodeLoader refer to Appendix A: CodeLoader Usage or the CodeLoader 4 instructions located
at http://www.national.com/timing/software/.
Before proceeding, be sure to follow the Quick Start section above to ensure proper connections.
1. Start CodeLoader 4 Application
Click “Start” “Programs” “CodeLoader 4” “CodeLoader 4”
The CodeLoader 4 program is installed by default to the CodeLoader 4 application group.
2. Select Device
Click “Select Device” “Clock Conditioners” “LMK04808B”
Once started CodeLoader 4 will load the
last used device. To load a new device
click “Select Device” from the menu bar,
then select the subgroup and finally device
to load. For this example, the LMK04808B
is chosen. Selecting the device does cause
the device to be programmed.
Figure 3 – Selecting the LMK04808B device