2. Quick Start
1. Connect a voltage of 5.0 volts to the Vcc SMA connector or terminal block. Device operates at
3.3 V using onboard LP3878-ADJ LDO.
2. Connect the uWire header via LPT or USB2ANY-uWire (See “EVM Software and
Communication” Section for more information).
3. Program the device with CodeLoader. CodeLoader is available for download at:
www.ti.com/tool/codeloader
a. Select correct LMK03806B from “Select Device Clock Conditioners” Menu.
b. Select a default mode from the “Mode” Menu. For the quick start use, “100 MHz
TCXO/XO Reference”
c. Ctrl-L must be pressed at least once to load all registers. Alternatively click menu Keyboard
Controls Load Device.
4. Measurements may be made at an active CLKout port via its SMA connector. Please see also
.
CLKout0
CLKout0*
Laptop or PC
For interfacing
the board
please see