Datasheet
t
CES
t
CS
D27 D26 D25 D24
t
CH
t
CWH
t
CWL
D23 D0 A3 A2 A1 A0
MSB LSB
DATAuWire
CLKuWire
LEuWire
t
ES
t
EWH
LMK03000, LMK03000C, LMK03000D, LMK03001
LMK03001C, LMK03001D, LMK03033, LMK03033C
www.ti.com
SNAS381O –NOVEMBER 2006–REVISED MARCH 2013
Electrical Characteristics
(1)
(continued)
(3.15 V ≤ Vcc ≤ 3.45 V, -40 °C ≤ T
A
≤ 85 °C, Differential Inputs/Outputs; Vboost=0; except as specified. Typical values
represent most likely parametric norms at Vcc = 3.3 V, T
A
= 25 °C, and at the Recommended Operation Conditions at the
time of product characterization and are not ensured).
Symbol Parameter Conditions Min Typ Max Units
Digital MICROWIRE Interfaces
(1)
V
IH
High-Level Input Voltage 1.6 Vcc V
V
IL
Low-Level Input Voltage 0.4 V
I
IH
High-Level Input Current V
IH
= Vcc -5.0 5.0 µA
I
IL
Low-Level Input Current V
IL
= 0 -5.0 5.0 µA
MICROWIRE Timing
t
CS
Data to Clock Set Up Time See Data Input Timing 25 ns
t
CH
Data to Clock Hold Time See Data Input Timing 8 ns
t
CWH
Clock Pulse Width High See Data Input Timing 25 ns
t
CWL
Clock Pulse Width Low See Data Input Timing 25 ns
t
ES
Clock to Enable Set Up Time See Data Input Timing 25 ns
t
CES
Enable to Clock Set Up Time See Data Input Timing 25 ns
t
EWH
Enable Pulse Width High See Data Input Timing 25 ns
(1) Applies to CLKuWire, DATAuWire, and LEuWire.
3.5 Serial Data Timing Diagram
Data bits set on the DATAuWire signal are clocked into a shift register, MSB first, on each rising edge of
the CLKuWire signal. On the rising edge of the LEuWire signal, the data is sent from the shift register to
the addressed register determined by the LSB bits. After the programming is complete the CLKuWire,
DATAuWire, and LEuWire signals should be returned to a low state. It is recommended that the slew rate
of CLKuWire, DATAuWire, and LEuWire should be at least 30 V/µs.
Copyright © 2006–2013, Texas Instruments Incorporated Electrical Specifications 11
Submit Documentation Feedback
Product Folder Links: LMK03000 LMK03000C LMK03000D LMK03001 LMK03001C LMK03001D LMK03033
LMK03033C