Datasheet

LMK01000
SNAS437G FEBRUARY 2008REVISED OCTOBER 2009
www.ti.com
Pin Descriptions (continued)
Pin # Pin Name I/O Description
28, 29 CLKin0,CLKin0* I CLKin 0 Input; Must be AC coupled
34, 35 CLKin1, CLKin1* I CLKin 1 Input; Must be AC coupled
36 Bias I Bias Bypass
38, 39 CLKout4, CLKout4* O Clock Output 4
41, 42 CLKout5, CLKout5* O Clock Output 5
44, 45 CLKout6, CLKout6* O Clock Output 6
47, 48 CLKout7, CLKout7* O Clock Output 7
DAP DAP - Die Attach Pad should be connected to ground.
The LMK01000 family is footprint compatible with the LMK03000/02000 family of devices. All CLKout pins are
pin-to-pin compatible, and CLKin0 and CLKin1 are equivalent to OSCin and Fin, respectively.
Device Configuration Information
Output LMK01000 LMK01010 LMK01020
CLKout0 LVDS LVDS LVPECL
CLKout1 LVDS LVDS LVPECL
CLKout2 LVDS LVDS LVPECL
CLKout3 LVPECL LVDS LVPECL
CLKout4 LVPECL LVDS LVPECL
CLKout5 LVPECL LVDS LVPECL
CLKout6 LVPECL LVDS LVPECL
CLKout7 LVPECL LVDS LVPECL
These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam
during storage or handling to prevent electrostatic damage to the MOS gates.
Absolute Maximum Ratings
(1) (2)
Parameter Symbol Ratings Units
Power Supply Voltage V
CC
-0.3 to 3.6 V
Input Voltage V
IN
-0.3 to (V
CC
+ 0.3) V
Storage Temperature Range T
STG
-65 to 150 °C
Lead Temperature (solder 4 s) T
L
+260 °C
Junction Temperature T
J
125 °C
(1) "Absolute Maximum Ratings" indicate limits beyond which damage to the device may occur, including inoperability and degradation of
device reliability and/or performance. Functional operation of the device and/or non-degradation at the Absolute Maximum Ratings or
other conditions beyond those indicated in the Recommended Operating Conditions is not implied. The Recommended Operating
Conditions indicate conditions at which the device is functional and the device should not be operated beyond such conditions.
(2) This device is a high performance integrated circuit with ESD handling precautions. Handling of this device should only be done at ESD
protected work stations. The device is rated to a HBM-ESD of > 2 kV, a MM-ESD of > 200 V, and a CDM-ESD of > 1.2 kV.
Recommended Operating Conditions
Parameter Symbol Min Typ Max Units
Ambient Temperature T
A
-40 25 85 °C
Power Supply Voltage V
CC
3.15 3.3 3.45 V
4 Submit Documentation Feedback Copyright © 2008–2009, Texas Instruments Incorporated
Product Folder Links: LMK01000