Absolute Maximum Ratings
(1)(2)(3)
ESD Tolerance
(4)
Human Body Model 2kV
Machine Model 200V
Charge-Device Model 750V
Positive Supply Voltage −0.5 to 6.0V
Differential Input Voltage 3V
Analog Input Voltage Range −0.5 to V
S
Digital Input Voltage −0.5 to V
S
Junction Temperature +150°C
Storage Temperature Range −65°C to +150°C
Soldering Information
http://www.ti.com/lit/SNOA549
(1) Absolute maximum ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is intended to be functional, but specific performance is not guaranteed. For guaranteed specifications and the test
conditions, see the Electrical Characteristics.
(2) Electrical table values apply only for factory testing conditions at the temperature indicated. Factory testing conditions result in very
limited self-heating of the device such that T
J
= T
A
. No guarantee of parametric performance is indicated in the electrical tables under
conditions of internal self-heating where T
J
> T
A
.
(3) If Military/Aerospace specified devices are required, please contact the Texas Instruments Sales Office/ Distributors for availability and
specifications.
(4) Human Body Model, applicable std. JESD22-A114C. Machine Model, applicable std. JESD22-A115-A. Field Induced Charge Device
Model, applicable std. JESD22-C101-C.
Operating Ratings
(1)
Supply Voltage (V
+
- V
−
) 2.7V to 5.5V
Operating Temperature Range −40°C to +125°C
Package (θ
JA
)
WSON-8 71°C/W
SOT-23-5 179°C/W
(1) Absolute maximum ratings indicate limits beyond which damage to the device may occur. Operating Ratings indicate conditions for
which the device is intended to be functional, but specific performance is not guaranteed. For guaranteed specifications and the test
conditions, see the Electrical Characteristics.
Copyright © 2010–2013, Texas Instruments Incorporated Submit Documentation Feedback 3